<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>indiriniz.com &#187; sekonder akım</title>
	<atom:link href="http://www.indiriniz.com/kompanzasyon/sekonder-akim/feed" rel="self" type="application/rss+xml" />
	<link>http://www.indiriniz.com</link>
	<description>Kompanzasyon Enerji kalitesi Günlüğü</description>
	<lastBuildDate>Thu, 14 May 2009 13:51:35 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.1</generator>
		<item>
		<title>Akım Transformatörlerinde İşaretlemeler 2</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/akim-transformatorlerinde-isaretlemeler-2-197.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/akim-transformatorlerinde-isaretlemeler-2-197.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 23:28:38 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Akım Gerilim Trafoları]]></category>
		<category><![CDATA[AG/OG]]></category>
		<category><![CDATA[akım]]></category>
		<category><![CDATA[akım trafosu]]></category>
		<category><![CDATA[Akım transformatörleri]]></category>
		<category><![CDATA[Akımlar]]></category>
		<category><![CDATA[aşırı gerilim]]></category>
		<category><![CDATA[sargı]]></category>
		<category><![CDATA[şebeke]]></category>
		<category><![CDATA[sekonder akım]]></category>
		<category><![CDATA[Sekonder Sargı]]></category>
		<category><![CDATA[transformatör]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=197</guid>
		<description><![CDATA[Bütün akım transformatörü etiketleri en azından aşağıdaki bilgileri içermelidir; - Kendisini açıkça belirleyecek şekilde, imalatçının adı veya tescilli markası - Seri numarası veya tip tanımı, mümkünse her ikisi - Primer ve sekonder anma akımları örnek; Kn = Ipn / Isn 100/5A gibi - Anma frekansı örnek; 50Hz gibi - Çıkış anma gücü ve onunla bağımlı [...]]]></description>
			<content:encoded><![CDATA[<p>Bütün akım transformatörü etiketleri en azından aşağıdaki bilgileri içermelidir;<br />
- Kendisini açıkça belirleyecek şekilde, imalatçının adı veya tescilli markası<span id="more-197"></span><br />
- Seri numarası veya tip tanımı, mümkünse her ikisi<br />
- Primer ve sekonder anma akımları örnek; Kn = Ipn / Isn 100/5A gibi<br />
- Anma frekansı örnek; 50Hz gibi<br />
- Çıkış anma gücü ve onunla bağımlı hassasiyet sınıfı<br />
Bunlarla ilgili ilave bilgiler ise,<br />
Örneğin hassasiyet sınıfı, ölçü emniyet faktörü, bunlarla ilgili anma çıkış gücü ile<br />
beraber aşağıdaki gibi,<br />
Örnek: 15VA – Sınıfı: 0.5 FS10 belirtilecek,<br />
ayrıca, akım transformatörünün akım ölçme sahasının genişletilmiş olması halinde;<br />
%120In &#8211; %150In veya %200In şeklinde belirtilecektir.<br />
Örnek: 15VA – sınıf:0.5 – FS10 – Ext %150 şeklinde belirtilecektir.<br />
<strong>Not: 1</strong><br />
- Anma etiketinde çıkış gücü ve hassasiyet sınıfı ile ilgili çeşitli kombinasyonları<br />
belirtecek bilgiler, örnek: 15VA – sınıf:0.5 / 30VA – sınıf:1.0<br />
ve hatta standard içinde olmayan veriler olması halinde;<br />
örnek: 15VA – sınıf:1.0 / 7VA – sınıf:0.5<br />
gibi bilgiler işaretlenebilir.<br />
Koruma transformatörlerinde ise normal olarak,<br />
Örnek: 30VA – sınıfı:5P 10<br />
örneğinde olduğu gibi, çıkış anma gücü ve bununla ilgili limit faktörlü akımdaki<br />
hassasiyet anma değeri, sonra P harfini takiben limit akım faktörü belirtilecektir.<br />
Ek bilgi kombinasyonlarının belirlenmesi halinde örneğin aşağıdaki şekilde,<br />
15VA – sınıf:0.5 veya 15VA – sınıf:1<br />
30VA – sınıf:1 veya 15VA sınıf:1 ext.%150<br />
30VA sınıf:5P 10 veya 15VA – Sınıf:5P 20<br />
gibi veriler işaretlenebilir.<br />
<strong>Not: 2</strong><br />
- Aynı sekonder sargının iki ayrı değerde sınıflandırılmış olması halinde,<br />
15VA – sınıf:0.5 30VA – sınıf:1 gibi de işaretlenebilir.<br />
- Cihazların çalışabileceği en yüksek gerilim (Örnek 1.2 veya 36kV)<br />
- İzolasyon anma seviyeleri (Örnek 70/170kV gibi)<br />
- veya kombine olarak (Örnek: 36/70/170kV gibi)<br />
Bütün anma bilgileri silinmez ve kolayca okunabilecek şekilde yazılmalıdır. Bütün<br />
bunlara ek olarak yer kalmış ise, aşağıdaki bilgilerinde verilmesinde fayda vardır.<br />
- Termik anma akımı, Ith 2.5 katından farklı ise, dinamik anma akımı, Idyn<br />
Örnek: Ith:13kA veya 13/40kA gibi)<br />
- İzolasyon sınıfı A’ dan farklı ise bildirilmelidir.<br />
Eğer, akım transformatöründe çeşitli izolasyon sınıflı malzemeler kullanılması halinde,<br />
bilhassa sargılarda limit ısınmada buna dayanacak izole malzeme sınıfı belirtilmelidir.<br />
- İki sekonder sargının olması halinde, her sargı için ona tekabül eden terminaller belirtilecektir.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/akim-transformatorlerinde-isaretlemeler-2-197.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Akım Transformatörleri Hakkında Tanımlamalar</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/akim-transformatorleri-hakkinda-tanimlamalar-155.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/akim-transformatorleri-hakkinda-tanimlamalar-155.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 21:46:01 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Akım Gerilim Trafoları]]></category>
		<category><![CDATA[Anma Primer Akımı]]></category>
		<category><![CDATA[primary current]]></category>
		<category><![CDATA[primary winding]]></category>
		<category><![CDATA[Primer Akım]]></category>
		<category><![CDATA[Primer Sargı]]></category>
		<category><![CDATA[rated primary current]]></category>
		<category><![CDATA[secondary circuit]]></category>
		<category><![CDATA[secondary current]]></category>
		<category><![CDATA[secondary winding]]></category>
		<category><![CDATA[sekonder akım]]></category>
		<category><![CDATA[Sekonder Devre]]></category>
		<category><![CDATA[Sekonder Sargı]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=155</guid>
		<description><![CDATA[Akım Trafoları ile ilgili kullanılan türkçe ve ingilizce tanımlar. tr=  Primer Sargı en= primary winding IEC 60044-1/1996-12 – Clause 2.1.3 Dönüştürülecek akımın geçtiği sargıdır. tr=  Sekonder Sargı en= secondary winding IEC 60044-1/1996-12 – Clause 2.1.4 Ölçü aletleri, sayaçlar, koruma ya da kumanda düzenlerinin akım devrelerini besleyen sargıdır. tr= Sekonder Devre en= secondary circuit IEC 60044-1/1996-12 [...]]]></description>
			<content:encoded><![CDATA[<p>Akım Trafoları ile ilgili kullanılan türkçe ve ingilizce tanımlar.</p>
<p>tr=  Primer Sargı<br />
en= primary winding<span id="more-155"></span></p>
<p>IEC 60044-1/1996-12 – Clause 2.1.3<br />
Dönüştürülecek akımın geçtiği sargıdır.</p>
<hr />tr=  Sekonder Sargı<br />
en= secondary winding</p>
<p>IEC 60044-1/1996-12 – Clause 2.1.4<br />
Ölçü aletleri, sayaçlar, koruma ya da kumanda düzenlerinin akım devrelerini<br />
besleyen sargıdır.</p>
<hr />tr= Sekonder Devre<br />
en= secondary circuit</p>
<p>IEC 60044-1/1996-12 – Clause 2.1.5<br />
Bir ölçü transformatörünün sekonder sargısından sağlanan bilgi işaretlerini<br />
alan dış devredir</p>
<hr />tr= Primer Akım<br />
en= primary current<br />
Bir akım transformatörünün primer sargısından geçen akımdır.</p>
<hr />
tr= Anma Primer Akımı<br />
en= rated primary current<br />
IEC 60044-1/1996-12 – Clause 2.1.6<br />
Bir akım transformatörünün tanıtılmasında kullanılan ve çalışma karakteristiklerinin<br />
(performans) dayandırıldığı primer akım değeridir.</p>
<hr />
tr= Sekonder Akım<br />
en= secondary current<br />
Bir akım transformatöründe, primer sargıdan akım geçmesi durumunda sekonder<br />
sargıdan geçen akımdır.</p>
<hr />
tr= Anma Sekonder Akımı<br />
en= rated secondary current<br />
IEC 60044-1/1996-12 – Clause 2.1.7<br />
Bir akım transformatörünün tanıtılmasında kullanılan ve çalışma karakteristiklerinin<br />
dayandırıldığı sekonder akım değeridir.</p>
<hr />
tr= Akım Transformatörünün Gerçek Dönüştürme Oranı<br />
en= actual transformation ratio of a current transformer<br />
IEC 60044-1/1996-12 – Clause 2.1.8<br />
Bir akım transformatöründe gerçek primer akımın, gerçek sekonder akıma oranıdır.</p>
<hr />
tr= Akım Transformatörünün Anma Dönüştürme Oranı<br />
en= rated transformation ratio of a current transformer<br />
IEC 60044-1/1996-12 – Clause 2.1.9<br />
Bir akım transformatöründe anma primer akımının, anma sekonder akımına oranıdır.</p>
<p><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 728x15, oluşturulma 20.11.2008 */
google_ad_slot = "6035974834";
google_ad_width = 728;
google_ad_height = 15;
//-->
</script>
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p> ]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/akim-transformatorleri-hakkinda-tanimlamalar-155.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Standard Akımlar</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/standard-akimlar-116.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/standard-akimlar-116.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 20:42:35 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Akım Gerilim Trafoları]]></category>
		<category><![CDATA[50Hz]]></category>
		<category><![CDATA[60Hz]]></category>
		<category><![CDATA[Akım transformatörleri]]></category>
		<category><![CDATA[Akımlar]]></category>
		<category><![CDATA[sekonder akım]]></category>
		<category><![CDATA[Standard]]></category>
		<category><![CDATA[√3]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=116</guid>
		<description><![CDATA[50 veya 60Hz için belirlenmiş standard akım değerleri; 1 – 2 – 5 &#8211; 10 – 12.5 – 15 – 20 – 25 – 30 – 40 – 50 – 60 – 75 – 80 A ve bunların on katları veya ondalıklarıdır. Akım transformatörlerinde sekonder akımlar; 1 &#8211; 2 – 5 veya 10A değerlerinden biri [...]]]></description>
			<content:encoded><![CDATA[<p>50 veya 60Hz için belirlenmiş standard akım değerleri;<br />
1 – 2 – 5 &#8211; 10 – 12.5 – 15 – 20 – 25 – 30 – 40 – 50 – 60 – 75 – 80 A<br />
ve bunların on katları veya ondalıklarıdır.<span id="more-116"></span><br />
Akım transformatörlerinde sekonder akımlar;<br />
1 &#8211; 2 – 5 veya 10A<br />
değerlerinden biri olmalıdır. Üçgen bağlı akım transformatörlerinde ise, yukarıda<br />
verilen sekonder akımların √3’ e bölünmüş değerleri alınmalıdır.</p>
<p><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 728x15, oluşturulma 20.11.2008 */
google_ad_slot = "6035974834";
google_ad_width = 728;
google_ad_height = 15;
//-->
</script>
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p> ]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/standard-akimlar-116.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

