<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>indiriniz.com &#187; şebeke kirliliği</title>
	<atom:link href="http://www.indiriniz.com/kompanzasyon/sebeke-kirliligi/feed" rel="self" type="application/rss+xml" />
	<link>http://www.indiriniz.com</link>
	<description>Kompanzasyon Enerji kalitesi Günlüğü</description>
	<lastBuildDate>Thu, 14 May 2009 13:51:35 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.1</generator>
		<item>
		<title>Akım Transformatörleri İçin Ek Veriler</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/akim-transformatorleri-icin-ek-veriler-199.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/akim-transformatorleri-icin-ek-veriler-199.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 23:34:52 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Akım Gerilim Trafoları]]></category>
		<category><![CDATA[60Hz]]></category>
		<category><![CDATA[AG/OG]]></category>
		<category><![CDATA[Akım Hatası]]></category>
		<category><![CDATA[Akım transformatörleri]]></category>
		<category><![CDATA[Faz Kayması]]></category>
		<category><![CDATA[Ölçü Akım]]></category>
		<category><![CDATA[şebeke kirliliği]]></category>
		<category><![CDATA[Transformatörlerinde]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=199</guid>
		<description><![CDATA[Ölçü Akım Transformatörlerinde Sınıflandırılma Tasarımı Akım transformatörleri en yüksek izin verilen yüzde akım yanılgısı, nominal anma akımı ve onunla ilgili sınıfı içinde tasarımlanır Standard Doğruluk Sınıfları IEC 60044-1/1996-12 – Clause 11.1.1 Ölçü akım transformatörleri için bu değerler aşağıdaki gibi tanımlanmıştır. 0.1 – 0.2 – 0.5 – 1.0 – 3.0 – 5.0 Ölçü Akım Transformatörlerinde Akım [...]]]></description>
			<content:encoded><![CDATA[<p>Ölçü Akım Transformatörlerinde Sınıflandırılma Tasarımı Akım transformatörleri en yüksek izin verilen yüzde akım yanılgısı, nominal anma akımı ve onunla ilgili sınıfı içinde tasarımlanır<span id="more-199"></span><br />
<strong>Standard Doğruluk Sınıfları</strong><br />
IEC 60044-1/1996-12 – Clause 11.1.1<br />
Ölçü akım transformatörleri için bu değerler aşağıdaki gibi tanımlanmıştır.<br />
0.1 – 0.2 – 0.5 – 1.0 – 3.0 – 5.0<br />
<strong>Ölçü Akım Transformatörlerinde Akım Hatası ve Faz Kayması</strong><br />
IEC 60044-1/1996-12 – Clause 11.2<br />
Doğruluk sınıfı, 0.1 – 0.2 – 0.5 – 1.0 olan akım transformatörlerinde, anma frekansında<br />
akım yanılgısı ve faz kayması, sekonder anma yükünün %25’ i ve %100’ ünde iken<br />
Tablo 8’ de verilen değerleri aşmamalıdır.<br />
<div id="attachment_200" class="wp-caption alignnone" style="width: 610px"><img src="http://www.indiriniz.com/wp-content/uploads/2009/03/adsiz-19.jpg" alt="Tablo 8" title="adsiz-19" width="600" height="180" class="size-full wp-image-200" /><p class="wp-caption-text">Tablo 8</p></div></p>
<p>0.2S ve 0.5S sınıfları olarak tanımlanan ve özel kullanımlarda 50mA….6A arası, yani anma<br />
akımının %1’ i ile %120’ si olarak sekonder anma akımı 5A olan ölçü transformatörlerinin<br />
anma frekansında ve anma yükünün %25’ i ile %100’ ünde akım yanılgısı ve faz kayması<br />
değerleri Tablo 9’ da verilen değerleri aşmamalıdır.</p>
<div id="attachment_202" class="wp-caption alignnone" style="width: 610px"><img src="http://www.indiriniz.com/wp-content/uploads/2009/03/adsiz-20.jpg" alt="Tablo 9" title="adsiz-20" width="600" height="121" class="size-full wp-image-202" /><p class="wp-caption-text">Tablo 9</p></div><br />
Bu tür akım transformatörleri, genelde 25/5A, 50/5A ve 100/5A veya bunların desimal<br />
çarpımlarınıda kapsayan primer akımlarına sahip ve sadece sekonder akımları 5A olan<br />
ölçü akım transformatörleri için tanımlanmıştır.<br />
Doğruluk sınıfı 3.0 ve 5.0 olan akım transformatörleri, anma frekansında akım yanılgısı<br />
sekonder yük anma yükünün %50 ile %100’ ü arasında iken, Tablo 10’ da verilen<br />
değerleri aşmamalıdır.<br />
3.0 ve 5.0 Sınıfı ölçü transformatörleri için faz kayması açı sınırları istenmemektedir.</p>
<p>Ölçü akım transformatörlerinin deneylerinde kullanılan sekonder yükün değeri 5VA’ e eşit veya daha büyük olduğunda güç katsayısı 0.8 endüktif olmalı; yük 5VA’ den küçük olduğunda güç katsayısı 1’ e eşit olmalıdır. Deney yükü hiç bir zaman 1VA’ den küçük olmamalıdır.<br />
<div id="attachment_205" class="wp-caption alignnone" style="width: 232px"><img src="http://www.indiriniz.com/wp-content/uploads/2009/03/adsiz-21.jpg" alt="Tablo 10" title="adsiz-21" width="222" height="174" class="size-full wp-image-205" /><p class="wp-caption-text">Tablo 10</p></div>
<p>Kaynak Alce</p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/akim-transformatorleri-icin-ek-veriler-199.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Akım Transformatörlerinde İşaretlemeler</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/akim-transformatorlerinde-isaretlemeler-188.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/akim-transformatorlerinde-isaretlemeler-188.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 23:23:22 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Akım Gerilim Trafoları]]></category>
		<category><![CDATA[Akım transformatörleri]]></category>
		<category><![CDATA[Akımlar]]></category>
		<category><![CDATA[alce elektrik]]></category>
		<category><![CDATA[Gerilim Transformatörleri]]></category>
		<category><![CDATA[Harmonik]]></category>
		<category><![CDATA[kompanzasyon trafosu]]></category>
		<category><![CDATA[ölçü transformatörleri]]></category>
		<category><![CDATA[şebeke kirliliği]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=188</guid>
		<description><![CDATA[Akım transformatörlerinde terminal işaretlemeleri aşağıdaki tanımları içermelidir. - Sekonder ve primer sargılar - Eğer sargılar bölümlü ise, bunların belirtilmesi - Sargı ve sargı bölümlerinin polariteleri - Var ise orta uçların belirtilmesi İşaretleme Metodu İşaretlemeler açıkça belirli ve gerek üzeri gerekse civarı silinmez olacaktır. İşaretlemeler, aşağıdaki harfleri ayrıca bunlara ait gerekli rakamlarıda taşıyacaklardır. Harfler blok büyük [...]]]></description>
			<content:encoded><![CDATA[<p>Akım transformatörlerinde terminal işaretlemeleri aşağıdaki tanımları içermelidir.<br />
- Sekonder ve primer sargılar<br />
- Eğer sargılar bölümlü ise, bunların belirtilmesi<br />
- Sargı ve sargı bölümlerinin polariteleri<br />
- Var ise orta uçların belirtilmesi<span id="more-188"></span><br />
<strong>İşaretleme Metodu</strong><br />
İşaretlemeler açıkça belirli ve gerek üzeri gerekse civarı silinmez olacaktır. İşaretlemeler,<br />
aşağıdaki harfleri ayrıca bunlara ait gerekli rakamlarıda taşıyacaklardır.<br />
Harfler blok büyük harf olacaktır.<br />
<strong>Kullanılacak İşaretlemeler</strong><br />
Akım transformatörleri terminal işaretlemeleri aşağıdaki gibi olacaktır.</p>
<p><div id="attachment_189" class="wp-caption alignnone" style="width: 514px"><img class="size-full wp-image-189" title="adsiz-15" src="http://www.indiriniz.com/wp-content/uploads/2009/03/adsiz-15.jpg" alt="Bir Dönüştürme Oranlı Transformatör" width="504" height="138" /><p class="wp-caption-text">Bir Dönüştürme Oranlı Transformatör</p></div><br />
<div id="attachment_190" class="wp-caption alignnone" style="width: 514px"><img src="http://www.indiriniz.com/wp-content/uploads/2009/03/adsiz-16.jpg" alt="Sekonderi Bir Ara Uçlu Transformatör" title="adsiz-16" width="504" height="138" class="size-full wp-image-190" /><p class="wp-caption-text">Sekonderi Bir Ara Uçlu Transformatör</p></div><br />
<div id="attachment_192" class="wp-caption alignnone" style="width: 514px"><img src="http://www.indiriniz.com/wp-content/uploads/2009/03/adsiz-17.jpg" alt="Seri Paralel Bağlamak İçin Primeri İki Kısımlı Transformatör" title="adsiz-17" width="504" height="200" class="size-full wp-image-192" /><p class="wp-caption-text">Seri Paralel Bağlamak İçin Primeri İki Kısımlı Transformatör</p></div><br />
<div id="attachment_195" class="wp-caption alignnone" style="width: 514px"><img src="http://www.indiriniz.com/wp-content/uploads/2009/03/adsiz-18.jpg" alt="Her Sargısı Ayrı Manyetik Çekirdek Üzerinde, İki Pr Sekonder Sargılı Transformatör" title="adsiz-18" width="504" height="200" class="size-full wp-image-195" /><p class="wp-caption-text">Her Sargısı Ayrı Manyetik Çekirdek Üzerinde, İki Pr Sekonder Sargılı Transformatör</p></div><br />
<strong>Şekil 7</strong>. Akım transformatörleri, primer/sekonder terminalleri işaretlemeleri</p>
<p>Kaynak Alce</p>
<p><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 728x15, oluşturulma 20.11.2008 */
google_ad_slot = "6035974834";
google_ad_width = 728;
google_ad_height = 15;
//-->
</script>
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p> ]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/akim-transformatorlerinde-isaretlemeler-188.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Nötrü Empedans Üzerinden Topraklanmış Şebeke</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/notru-empedans-uzerinden-topraklanmis-sebeke-138.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/notru-empedans-uzerinden-topraklanmis-sebeke-138.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 21:06:54 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Akım Gerilim Trafoları]]></category>
		<category><![CDATA[akım trafosu]]></category>
		<category><![CDATA[Akımlar]]></category>
		<category><![CDATA[Empedans]]></category>
		<category><![CDATA[endüksiyon]]></category>
		<category><![CDATA[Gerilim Transformatörleri]]></category>
		<category><![CDATA[Harmonik]]></category>
		<category><![CDATA[Kompanzasyon]]></category>
		<category><![CDATA[kompanzasyon trafosu]]></category>
		<category><![CDATA[ölçü transformatörleri]]></category>
		<category><![CDATA[şebeke]]></category>
		<category><![CDATA[şebeke kirliliği]]></category>
		<category><![CDATA[Topraklanmış Şebeke]]></category>
		<category><![CDATA[transformatör]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=138</guid>
		<description><![CDATA[Nötrün bir veya birkaç noktadan toprakla toprakla kısa devrede bu akımı sınırlamak üzere, empedans ile topraklanmış şebekedir.Akım Transformatörleri (IEC 60044-1/1996-12 – Clause 2.1.20) Gerilim Transformatörleri (IEC 60044-2/1997-02 – Clause 2.1.22) Kaynak: Alce Elektrik]]></description>
			<content:encoded><![CDATA[<p>Nötrün bir veya birkaç noktadan toprakla toprakla kısa devrede bu akımı sınırlamak üzere,<br />
empedans ile topraklanmış şebekedir.<span id="more-138"></span>Akım Transformatörleri (IEC 60044-1/1996-12 – Clause 2.1.20)<br />
Gerilim Transformatörleri (IEC 60044-2/1997-02 – Clause 2.1.22)</p>
<p>Kaynak: Alce Elektrik</p>
<p><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 728x15, oluşturulma 20.11.2008 */
google_ad_slot = "6035974834";
google_ad_width = 728;
google_ad_height = 15;
//-->
</script>
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p> ]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/notru-empedans-uzerinden-topraklanmis-sebeke-138.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Nötrü Direkt Topraklanmış Şebeke</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/notru-direkt-topraklanmis-sebeke-136.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/notru-direkt-topraklanmis-sebeke-136.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 21:05:04 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Akım Gerilim Trafoları]]></category>
		<category><![CDATA[50Hz]]></category>
		<category><![CDATA[60Hz]]></category>
		<category><![CDATA[AG/OG]]></category>
		<category><![CDATA[aşırı gerilim]]></category>
		<category><![CDATA[enerji nakil hattı]]></category>
		<category><![CDATA[gerilim]]></category>
		<category><![CDATA[Gerilim Transformatörleri]]></category>
		<category><![CDATA[Nötr]]></category>
		<category><![CDATA[şebeke]]></category>
		<category><![CDATA[şebeke kirliliği]]></category>
		<category><![CDATA[Topraklanmış Şebeke]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=136</guid>
		<description><![CDATA[Nötrü bir veya birkaç noktadan direkt olarak topraklanmış şebekedir. Not: - Şebekenin bütün değişik durumlarında sıfır bileşen reaktansınıın pozitif bileşen reaktansına oranı 3’ den ve sıfır bileşen direncinin pozitif bileşen reaktansına oranı 1’ den küçük ise, bu koşul yaklaşık olarak yerine getirilmiş sayılır. - Belirli bir yerde nötrü etkin olarak topraklanmış üç fazlı şebeke, bu [...]]]></description>
			<content:encoded><![CDATA[<p>Nötrü bir veya birkaç noktadan direkt olarak topraklanmış şebekedir.<br />
Not:<br />
- Şebekenin bütün değişik durumlarında sıfır bileşen reaktansınıın pozitif bileşen reaktansına<span id="more-136"></span><br />
oranı 3’ den ve sıfır bileşen direncinin pozitif bileşen reaktansına oranı 1’ den küçük ise,<br />
bu koşul yaklaşık olarak yerine getirilmiş sayılır.<br />
- Belirli bir yerde nötrü etkin olarak topraklanmış üç fazlı şebeke, bu yerdeki topraklama<br />
katsayısı 1.4’ ü geçmeyen şebekedir.</p>
<p>Akım Transformatörleri (IEC 60044-1/1996-12 – Clause 2.1.19)<br />
Gerilim Transformatörleri (IEC 60044-2/1997-02 – Clause 2.1.21)</p>
<p>Kaynak: Alce Elektrik</p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/notru-direkt-topraklanmis-sebeke-136.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Keramik İzoleli Harici Ölçü Transformatörlerinde; Çevre Kirlilik Seviyelerine Göre Krepaj Mesafeleri</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/keramik-izoleli-harici-olcu-transformatorlerinde-cevre-kirlilik-seviyelerine-gore-krepaj-mesafeleri-119.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/keramik-izoleli-harici-olcu-transformatorlerinde-cevre-kirlilik-seviyelerine-gore-krepaj-mesafeleri-119.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 20:46:32 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Akım Gerilim Trafoları]]></category>
		<category><![CDATA[3.6 kv]]></category>
		<category><![CDATA[akım trafosu]]></category>
		<category><![CDATA[Akım transformatörleri]]></category>
		<category><![CDATA[alce elektrik]]></category>
		<category><![CDATA[atlama mesafesi]]></category>
		<category><![CDATA[kompanzasyon trafosu]]></category>
		<category><![CDATA[Krepaj Mesafeleri]]></category>
		<category><![CDATA[kV]]></category>
		<category><![CDATA[şebeke]]></category>
		<category><![CDATA[şebeke kirliliği]]></category>
		<category><![CDATA[Toprak İle Faz]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=119</guid>
		<description><![CDATA[Akım Transformatörleri (IEC 60044-1/1996-12 – Clause 5.1.6.1) Gerilim Transformatörleri (IEC 60044-2/1997-02 – Clause 6.1.5.1) Çevre Kirlilik Seviyelerine Göre Krepaj Mesafeleri: Kirlilik Seviyesi Toprak İle Faz Arası Krepaj (mm) (Faz arası gerilim ile çarpılmak üzere katsayı) 1- HAFİF 16 2- ORTA 20 3- AĞIR 25 4- ÇOK AĞIR 31 Not: - Çok temiz ortamlarda, işletmedeki tecrübelere [...]]]></description>
			<content:encoded><![CDATA[<p>Akım Transformatörleri (IEC 60044-1/1996-12 – Clause 5.1.6.1)<br />
Gerilim Transformatörleri (IEC 60044-2/1997-02 – Clause 6.1.5.1)<br />
Çevre Kirlilik Seviyelerine Göre Krepaj Mesafeleri:<span id="more-119"></span><br />
Kirlilik Seviyesi Toprak İle Faz Arası Krepaj (mm)<br />
(Faz arası gerilim ile çarpılmak üzere katsayı)<br />
1- HAFİF 16<br />
2- ORTA 20<br />
3- AĞIR 25<br />
4- ÇOK AĞIR 31<br />
Not:<br />
- Çok temiz ortamlarda, işletmedeki tecrübelere istinaden bu değer 16 katsayısının altında<br />
tutulabilir. Ancak, 12’ den aşağı düşürülmemesi tavsiye edilir.<br />
- TS 620/1978 Standardına göre;<br />
Yüzeysel atlama uzaklığı (krepaj) en yüksek şebeke gerilimi 3.6kV’ tan daha büyük olan<br />
akım transformatörleri için en yüksek şebeke anma geriliminin her kV’ u başına;<br />
Normal Kirli Bölgelerde 23/1.5 mm/kV<br />
Çok Kirli Bölgelerde 23 mm/kV<br />
değerlerinden az olmamalıdır.</p>
<p>En yüksek şebeke anma geriliminin 3.6kV veya daha düşük olması durumunda krepaj;<br />
Normal Kirli Bölgelerde 75 mm<br />
Çok Kirli Bölgelerde 125 mm<br />
değerlerinden az olmamalıdır.<br />
- TS 718/1978 Standardında ise bu konuda bir veri bulunmamaktadır</p>
<p>kaynak: Alce Elektrik</p>