<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>indiriniz.com &#187; Rutin testler</title>
	<atom:link href="http://www.indiriniz.com/kompanzasyon/rutin-testler/feed" rel="self" type="application/rss+xml" />
	<link>http://www.indiriniz.com</link>
	<description>Kompanzasyon Enerji kalitesi Günlüğü</description>
	<lastBuildDate>Thu, 14 May 2009 13:51:35 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.1</generator>
		<item>
		<title>Rutin Testler</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/rutin-testler-304.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/rutin-testler-304.html#comments</comments>
		<pubDate>Fri, 17 Apr 2009 22:33:09 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Akım Gerilim Trafoları]]></category>
		<category><![CDATA[Hataların belirlenmesi deneyleri]]></category>
		<category><![CDATA[Kısmi boşalmanın ölçülmesi deneyi]]></category>
		<category><![CDATA[Primer sargının şebeke frekanslı gerilime dayanma deneyi]]></category>
		<category><![CDATA[Rutin testler]]></category>
		<category><![CDATA[Sargı bölümleri arası şebeke frekanslı gerilime dayanma deneyi]]></category>
		<category><![CDATA[Sekonder sargıların şebeke frekanslı gerilime dayanma deneyi]]></category>
		<category><![CDATA[Terminal işaretlemelerinin kontrolu]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=304</guid>
		<description><![CDATA[Rutin Testler Aşağıda tanımlanan testler tüm transformatörlere uygulanmalıdır. - Terminal işaretlemelerinin kontrolu (IEC 60044-2 Clause 9.1) - Primer sargının şebeke frekanslı gerilime dayanma deneyi (IEC 60044-2 Clause 9.2) - Kısmi boşalmanın ölçülmesi deneyi (IEC 60044-2 Clause 9.2.4) - Sekonder sargıların şebeke frekanslı gerilime dayanma deneyi (IEC 60044-2 Clause 9.3) - Sargı bölümleri arası şebeke frekanslı [...]]]></description>
			<content:encoded><![CDATA[<p>Rutin Testler<br />
Aşağıda tanımlanan testler tüm transformatörlere uygulanmalıdır.<br />
- Terminal işaretlemelerinin kontrolu (IEC 60044-2 Clause 9.1)<br />
- Primer sargının şebeke frekanslı gerilime dayanma deneyi (IEC 60044-2 Clause 9.2)<br />
- Kısmi boşalmanın ölçülmesi deneyi (IEC 60044-2 Clause 9.2.4)<span id="more-304"></span><br />
- Sekonder sargıların şebeke frekanslı gerilime dayanma deneyi (IEC 60044-2 Clause 9.3)<br />
- Sargı bölümleri arası şebeke frekanslı gerilime dayanma deneyi (IEC 60044-2 Clause 9.3)<br />
- Hataların belirlenmesi deneyleri (IEC 60044-2 Clause 12.4 ve 13.7)<br />
Yukarıda tanımlanan rutin deneylerin sırası tanımlı değildir. Ancak, en son olarak<br />
hataların belirlenmesi deneyi uygulanacaktır.<br />
Şebeke frekanslı dayanım gerilimi deneyinin tekrarlanması durumunda, bu deney<br />
belirlenmiş deney gerilminin %80’ inde yapılır.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/rutin-testler-304.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Testlerin Sınıflandırılması</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/testlerin-siniflandirilmasi-184.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/testlerin-siniflandirilmasi-184.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 23:10:15 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Akım Gerilim Trafoları]]></category>
		<category><![CDATA[alce]]></category>
		<category><![CDATA[ölçü transformatörleri]]></category>
		<category><![CDATA[Özel testler]]></category>
		<category><![CDATA[Rutin testler]]></category>
		<category><![CDATA[tip test]]></category>
		<category><![CDATA[Tip testleri]]></category>
		<category><![CDATA[transformatör]]></category>
		<category><![CDATA[transformatöre uygulanan testler]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=184</guid>
		<description><![CDATA[Testlerin Sınıflandırılması Ölçü transformatörleri testleri, - Tip testleri - Rutin testler - Özel testler olarak sınıflandırılmıştır. Tip Test Transformatörlerin, rutin deneylerle kapsanmayan belirtilmiş özelliklere uygunluğunu göstermek için diğer transformatörleri temsil eden bir transformatör üzerinde yapılan testlerdir. Not: Yapısı ve beyan değerleri tam olarak eşdeğerse bu transformatörün diğerlerini temsil ettiği düşünülür, fakat beyan değerlerinde veya diğer [...]]]></description>
			<content:encoded><![CDATA[<p>Testlerin Sınıflandırılması Ölçü transformatörleri testleri,<br />
- Tip testleri<br />
- Rutin testler<br />
- Özel testler<br />
olarak sınıflandırılmıştır.<span id="more-184"></span><br />
<strong>Tip Test</strong><br />
Transformatörlerin, rutin deneylerle kapsanmayan belirtilmiş özelliklere uygunluğunu<br />
göstermek için diğer transformatörleri temsil eden bir transformatör üzerinde yapılan<br />
testlerdir.<br />
<strong>Not:</strong><br />
Yapısı ve beyan değerleri tam olarak eşdeğerse bu transformatörün diğerlerini temsil ettiği<br />
düşünülür, fakat beyan değerlerinde veya diğer karakteristiklerinde küçük farklılıkları<br />
bulunan bir transformatörde yapılmış ise, bu tip test de geçerli olabilir. Ancak bu fark<br />
önceden belirtilmelidir.<br />
<strong>Rutin Test</strong><br />
Tek tek her transformatöre uygulanan testlerdir.<br />
<strong>Özel Test</strong><br />
Tip ve rutin testler dışında, imalatçı ile müşterinin belirlediği testlerdir ve önceden<br />
belirlenmelidir.</p>
<p>Kaynak: Alce</p>
<p><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 728x15, oluşturulma 20.11.2008 */
google_ad_slot = "6035974834";
google_ad_width = 728;
google_ad_height = 15;
//-->
</script>
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p> ]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/testlerin-siniflandirilmasi-184.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

