<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>indiriniz.com &#187; Özel testler</title>
	<atom:link href="http://www.indiriniz.com/kompanzasyon/ozel-testler/feed" rel="self" type="application/rss+xml" />
	<link>http://www.indiriniz.com</link>
	<description>Kompanzasyon Enerji kalitesi Günlüğü</description>
	<lastBuildDate>Thu, 14 May 2009 13:51:35 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.1</generator>
		<item>
		<title>Özel Testler</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/ozel-testler-306.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/ozel-testler-306.html#comments</comments>
		<pubDate>Sat, 18 Apr 2009 10:35:42 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Akım Gerilim Trafoları]]></category>
		<category><![CDATA[Darbe gerilimi]]></category>
		<category><![CDATA[Kapasite ve dielektrik kayıp faktörünün ölçülmesi deneyi]]></category>
		<category><![CDATA[Mekanik testler]]></category>
		<category><![CDATA[negatif darbe gerilimi]]></category>
		<category><![CDATA[negatif polarite]]></category>
		<category><![CDATA[Özel testler]]></category>
		<category><![CDATA[Primer sargının kesik darbe deneyi]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=306</guid>
		<description><![CDATA[Özel Testler Bu testler üretici ile müşteri arasında anlaşma sonucu uygulanacak testlerdir. - Primer sargının kesik darbe deneyi (IEC 60044-2 Clause 10.1) Bu deney sadece negatif polarite ile gerçekleştirilir ve negatif darbe gerilimi ile kombine olarak aşağıdaki şekilde uygulanır. - Darbe gerilimi, IEC 60-1’ e göre belirlenmiş ve alın tarafı 2 ile 5μ saniyeli kesik [...]]]></description>
			<content:encoded><![CDATA[<p>Özel Testler<br />
Bu testler üretici ile müşteri arasında anlaşma sonucu uygulanacak testlerdir.<br />
- Primer sargının kesik darbe deneyi (IEC 60044-2 Clause 10.1)<br />
Bu deney sadece negatif polarite ile gerçekleştirilir ve negatif darbe gerilimi<br />
ile kombine olarak aşağıdaki şekilde uygulanır.<br />
- Darbe gerilimi, IEC 60-1’ e göre belirlenmiş ve alın tarafı 2 ile 5μ saniyeli kesik<br />
darbe ile gerçekleştirilir. Darbe gerilimi tepe değeri ise, Tablo 1’ e göre tespit<br />
edilir.<span id="more-306"></span><br />
OG gerilim transformatörlerinde test,<br />
- Bir adet tam darbe<br />
- İki adet kesik darbe<br />
- Ondört adet tam darbe<br />
geriliminin uygulanması ile gerçekleştirilir.<br />
Topraklanmamış gerilim transformatörlerinde ise, iki adet kesik darbe ve takriben<br />
yukarıdaki miktarın yarı miktarda tam darbe geriliminin her uca uygulanması ile<br />
gerçekleştirilir.<br />
- Kapasite ve dielektrik kayıp faktörünün ölçülmesi deneyi (IEC 60044-2 Clause 10.2)<br />
Bu test sadece Um≥72.5kV yağ izoleli gerilim transformatörlerine uygulanmaktadır.<br />
- Mekanik testler (IEC 60044-2 Clause 10.3)<br />
Bu test sadece Um≥72.5kV yağ izoleli gerilim transformatörlerine uygulanmaktadır.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/ozel-testler-306.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Genişletilmiş Ölçü Akım Transformatörleri Ölçme Sahaları</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/genisletilmis-olcu-akim-transformatorleri-olcme-sahalari-207.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/genisletilmis-olcu-akim-transformatorleri-olcme-sahalari-207.html#comments</comments>
		<pubDate>Mon, 30 Mar 2009 20:02:08 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Akım Gerilim Trafoları]]></category>
		<category><![CDATA[Akım Hatası]]></category>
		<category><![CDATA[Akım transformatörleri]]></category>
		<category><![CDATA[endüstri]]></category>
		<category><![CDATA[Harmonik]]></category>
		<category><![CDATA[kablo]]></category>
		<category><![CDATA[kompanzasyon trafosu]]></category>
		<category><![CDATA[kondansatör]]></category>
		<category><![CDATA[Ölçme Sahaları]]></category>
		<category><![CDATA[ölçü]]></category>
		<category><![CDATA[ölçü transformatörleri]]></category>
		<category><![CDATA[Özel testler]]></category>
		<category><![CDATA[Topraklanmış Şebeke]]></category>
		<category><![CDATA[transformatör]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=207</guid>
		<description><![CDATA[Ölçü akım transformatörleri 0.1 ile 1.0 doğruluk sınıfları içerisinde, aşağıdaki şartı yerine getirmek koşuluyla, genişletilmiş akım ölçme sahası için markalanabilirler. - Akım transformatörünün sürekli termik akımı, primer anma akımının yüzde olarak genişletilmişi olarak tarif edilmesi halinde, akım yanılgısı ve faz kayması değerleri, Tablo 8 ’ de primer akımın %120 primer akımı için verilen sınır değerleri [...]]]></description>
			<content:encoded><![CDATA[<p>Ölçü akım transformatörleri 0.1 ile 1.0 doğruluk sınıfları içerisinde, aşağıdaki şartı<br />
yerine getirmek koşuluyla, genişletilmiş akım ölçme sahası için markalanabilirler.<span id="more-207"></span><br />
- Akım transformatörünün sürekli termik akımı, primer anma akımının yüzde olarak<br />
genişletilmişi olarak tarif edilmesi halinde,<br />
akım yanılgısı ve faz kayması değerleri, Tablo 8<br />
’ de primer akımın %120 primer<br />
akımı için verilen sınır değerleri aşmamalıdır.<br />
Standard primer akım genişleme sahaları, primer nominal akımın yüzdesi olarak,<br />
120% &#8211; 150% &#8211; 200%<br />
şeklinde tarif edilmiştir.<br />
Not:<br />
TS 620/1978 Paragraf 1.2.2.3b’ ye bakınız.<br />
IEC 60044-1/1996-12 – Clause 11.3</p>
<p><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 728x15, oluşturulma 20.11.2008 */
google_ad_slot = "6035974834";
google_ad_width = 728;
google_ad_height = 15;
//-->
</script>
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p> ]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/genisletilmis-olcu-akim-transformatorleri-olcme-sahalari-207.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Akım Transformatörlerinde Testler</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/akim-transformatorlerinde-testler-186.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/akim-transformatorlerinde-testler-186.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 23:15:17 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Akım Gerilim Trafoları]]></category>
		<category><![CDATA[aşırı gerilime dayanma deneyi]]></category>
		<category><![CDATA[darbe gerilim deneyi]]></category>
		<category><![CDATA[Darbe gerilimi]]></category>
		<category><![CDATA[dayanım deneyi]]></category>
		<category><![CDATA[frekans]]></category>
		<category><![CDATA[izolasyon deneyi]]></category>
		<category><![CDATA[Mekanik deneyler]]></category>
		<category><![CDATA[ölçü]]></category>
		<category><![CDATA[Özel testler]]></category>
		<category><![CDATA[şebeke]]></category>
		<category><![CDATA[Sekonder Sargı]]></category>
		<category><![CDATA[Sıcaklık artış deneyi]]></category>
		<category><![CDATA[spesifikasyon]]></category>
		<category><![CDATA[Tip testleri]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=186</guid>
		<description><![CDATA[Tip Testleri İlgili bölümlerde, nasıl yapılacağı belirtilen aşağıdaki testlerdir; - Kısa süreli akım deneyleri (Ith, Idyn) (IEC 60044-1/1996-12 – Clause 7.1) - Sıcaklık artış deneyi (IEC 60044-1/1996-12 – Clause 7.2) - Darbe gerilimine dayanım deneyi (IEC 60044-1/1996-12 – Clause 7.3.2) - Hataların belirlenmesi deneyleri (1/1996-12 – C IEC 60044- lause 11.4 and/or 12.4, 11.6, 12.5 [...]]]></description>
			<content:encoded><![CDATA[<p><strong>Tip Testleri</strong><br />
İlgili bölümlerde, nasıl yapılacağı belirtilen aşağıdaki testlerdir;<br />
- Kısa süreli akım deneyleri (Ith, Idyn) (IEC 60044-1/1996-12 – Clause 7.1)<br />
- Sıcaklık artış deneyi (IEC 60044-1/1996-12 – Clause 7.2)<span id="more-186"></span><br />
- Darbe gerilimine dayanım deneyi (IEC 60044-1/1996-12 – Clause 7.3.2)<br />
- Hataların belirlenmesi deneyleri (1/1996-12 – C IEC 60044-<br />
lause 11.4 and/or 12.4, 11.6, 12.5 and 14.3)<br />
- Radyo girişim geriliminin ölçülmesi deneyi Um≥123kV (IEC 60044-1/1996-12 – Clause 7.5)<br />
Bütün bu testlere ilişkin bilgiler, başka bir spesifikasyon olmaması<br />
durumunda, aynı akım transformatöründen elde edilir.<br />
<strong>Rutin Testler</strong><br />
Her transformatöre aşağıdaki testler uygulanır.<br />
- Terminallerin işaretlenmesi (IEC 60044-1/1996-12 – Clause 8.1/10.1)<br />
- Primer sargının şebeke frekansında gerilime dayanma deneyi (IEC 60044-1/1996-12 – Clause 8.2.1)<br />
- Sekonder sargının şebeke frekansında gerilime dayanma deneyi (IEC 60044-1/1996-12 – Clause 8.3 or 14.4.4)<br />
- Kısmi boşalmanın ölçülmesi deneyi (IEC 60044-1/1996-12 – Clause 8.2.2)<br />
- Sarımlar arası aşırı gerilime dayanma deneyi (IEC 60044-1/1996-12 – Clause 8.4)<br />
- Transformatör sargılar arası izolasyon deneyi (IEC 60044-1/1996-12 – Clause 8.3 )<br />
- Hataların belirlenmesi deneyleri (IEC 60044-1/1996-12 – Clause 11.5 and/or<br />
12.4, 11.6, 12.6 and 14.4)<br />
<strong>Özel Testler</strong><br />
- Kesik darbe gerilim deneyi (IEC 60044-1/1996-12 – Clause 9.1)<br />
- Kapasite ve dielektrik kayıp faktörünün ölçülmesi (Um≥72.5kV) (IEC 60044-1/1996-12 – Clause 9.2)<br />
- Primer sargıda çoklu kesik darbe gerilim deneyi (Um≥300kV) (IEC 60044-1/1996-12 – Annex B)<br />
- Mekanik deneyler (Um≥72.5kV) (IEC 60044-1/1996-12 – Clause 9.3)</p>
<p><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 728x15, oluşturulma 20.11.2008 */
google_ad_slot = "6035974834";
google_ad_width = 728;
google_ad_height = 15;
//-->
</script>
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p> ]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/akim-transformatorlerinde-testler-186.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Testlerin Sınıflandırılması</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/testlerin-siniflandirilmasi-184.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/testlerin-siniflandirilmasi-184.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 23:10:15 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Akım Gerilim Trafoları]]></category>
		<category><![CDATA[alce]]></category>
		<category><![CDATA[ölçü transformatörleri]]></category>
		<category><![CDATA[Özel testler]]></category>
		<category><![CDATA[Rutin testler]]></category>
		<category><![CDATA[tip test]]></category>
		<category><![CDATA[Tip testleri]]></category>
		<category><![CDATA[transformatör]]></category>
		<category><![CDATA[transformatöre uygulanan testler]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=184</guid>
		<description><![CDATA[Testlerin Sınıflandırılması Ölçü transformatörleri testleri, - Tip testleri - Rutin testler - Özel testler olarak sınıflandırılmıştır. Tip Test Transformatörlerin, rutin deneylerle kapsanmayan belirtilmiş özelliklere uygunluğunu göstermek için diğer transformatörleri temsil eden bir transformatör üzerinde yapılan testlerdir. Not: Yapısı ve beyan değerleri tam olarak eşdeğerse bu transformatörün diğerlerini temsil ettiği düşünülür, fakat beyan değerlerinde veya diğer [...]]]></description>
			<content:encoded><![CDATA[<p>Testlerin Sınıflandırılması Ölçü transformatörleri testleri,<br />
- Tip testleri<br />
- Rutin testler<br />
- Özel testler<br />
olarak sınıflandırılmıştır.<span id="more-184"></span><br />
<strong>Tip Test</strong><br />
Transformatörlerin, rutin deneylerle kapsanmayan belirtilmiş özelliklere uygunluğunu<br />
göstermek için diğer transformatörleri temsil eden bir transformatör üzerinde yapılan<br />
testlerdir.<br />
<strong>Not:</strong><br />
Yapısı ve beyan değerleri tam olarak eşdeğerse bu transformatörün diğerlerini temsil ettiği<br />
düşünülür, fakat beyan değerlerinde veya diğer karakteristiklerinde küçük farklılıkları<br />
bulunan bir transformatörde yapılmış ise, bu tip test de geçerli olabilir. Ancak bu fark<br />
önceden belirtilmelidir.<br />
<strong>Rutin Test</strong><br />
Tek tek her transformatöre uygulanan testlerdir.<br />
<strong>Özel Test</strong><br />
Tip ve rutin testler dışında, imalatçı ile müşterinin belirlediği testlerdir ve önceden<br />
belirlenmelidir.</p>
<p>Kaynak: Alce</p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/testlerin-siniflandirilmasi-184.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>