<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>indiriniz.com &#187; Ölçü Akım</title>
	<atom:link href="http://www.indiriniz.com/kompanzasyon/olcu-akim/feed" rel="self" type="application/rss+xml" />
	<link>http://www.indiriniz.com</link>
	<description>Kompanzasyon Enerji kalitesi Günlüğü</description>
	<lastBuildDate>Thu, 14 May 2009 13:51:35 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.1</generator>
		<item>
		<title>Ölçü Akım Transformatörlerinde Akım Yanılgısı ve Faz Kayması Hataları Rutin Testleri</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-akim-transformatorlerinde-akim-yanilgisi-ve-faz-kaymasi-hatalari-rutin-testleri-212.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-akim-transformatorlerinde-akim-yanilgisi-ve-faz-kaymasi-hatalari-rutin-testleri-212.html#comments</comments>
		<pubDate>Mon, 30 Mar 2009 20:14:36 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Akım Gerilim Trafoları]]></category>
		<category><![CDATA[Akım Yanılgısı]]></category>
		<category><![CDATA[Faz Kayması]]></category>
		<category><![CDATA[Ölçü Akım]]></category>
		<category><![CDATA[Rutin Test]]></category>
		<category><![CDATA[Transformatörleri]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=212</guid>
		<description><![CDATA[Prensip itibarı ile yukarıdaki paragraftaki testlerin aynısıdır. Fakat bu testler akım bölümleri sayısında veya yük çeşidinde azaltma yapılarak yerine getirilebilir. Ancak, bunun tip testinde benzeri transformatörlerde gösterilerek bu şekilde bir daraltmalı testin akım yanılgısı ile faz kaymalarının bunlara uygun olma olasılığının kanıtlanması gerekir. kaynak alce elektrik]]></description>
			<content:encoded><![CDATA[<p>Prensip itibarı ile yukarıdaki paragraftaki testlerin aynısıdır. Fakat bu testler akım<br />
bölümleri sayısında veya yük çeşidinde azaltma yapılarak yerine getirilebilir.<span id="more-212"></span><br />
Ancak, bunun tip testinde benzeri transformatörlerde gösterilerek bu şekilde bir<br />
daraltmalı testin akım yanılgısı ile faz kaymalarının bunlara uygun olma olasılığının<br />
kanıtlanması gerekir.</p>
<p>kaynak alce elektrik</p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-akim-transformatorlerinde-akim-yanilgisi-ve-faz-kaymasi-hatalari-rutin-testleri-212.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Ölçü Akım Transformatörlerinde Akım Yanılgısı ve Faz Kayması Hataları Tip Testleri</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-akim-transformatorlerinde-akim-yanilgisi-ve-faz-kaymasi-hatalari-tip-testleri-209.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-akim-transformatorlerinde-akim-yanilgisi-ve-faz-kaymasi-hatalari-tip-testleri-209.html#comments</comments>
		<pubDate>Mon, 30 Mar 2009 20:06:23 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Akım Gerilim Trafoları]]></category>
		<category><![CDATA[Akım Yanılgısı]]></category>
		<category><![CDATA[Faz Kayması]]></category>
		<category><![CDATA[Hataları]]></category>
		<category><![CDATA[Ölçü Akım]]></category>
		<category><![CDATA[Tip testleri]]></category>
		<category><![CDATA[Transformatörlerinde]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=209</guid>
		<description><![CDATA[burada bahsettiğimiz bilgilere göre oran tip testleri uygunluğu, ölçü transformatörünün doğruluk sınıfının 0.1 ile 1.0 olması durumunda, - doğruluk sınıfında, - Tablo 8’ de belirtilen her bir akımda, - Nominal yükünün 25% ve 100%’ ünde akım yanılgısı ve faz kayması ölçü değerleri verilen sınır değerleri aşmamak üzere test edilir (deney yükü hiç bir zaman 1VA’ [...]]]></description>
			<content:encoded><![CDATA[<p><a href="http://www.indiriniz.com/akim-gerilim-trafolari/akim-transformatorlerinde-testler-186.html">burada </a>bahsettiğimiz bilgilere göre oran tip testleri uygunluğu, ölçü transformatörünün doğruluk<span id="more-209"></span><br />
sınıfının 0.1 ile 1.0 olması durumunda,<br />
- doğruluk sınıfında,<br />
- Tablo 8’ de belirtilen her bir akımda,<br />
- Nominal yükünün 25% ve 100%’ ünde<br />
akım yanılgısı ve faz kayması ölçü değerleri verilen sınır değerleri aşmamak üzere<br />
test edilir (deney yükü hiç bir zaman 1VA’ den küçük olamaz).<br />
Transformatörün %120’ den daha büyük sınırları genişletilmiş primer akımı olması<br />
durumunda, Tablo 8’ deki 120% değerleri baz alınmak üzere, belirlenmiş genişletilmiş<br />
anma akımında test gerçekleştirilir.<br />
Hassasiyet sınıfı, 3.0 ve 5.0 olan akım transformatörlerinin uygunluğu, nominal akımının<br />
50% ve 120%’ sinde ve anma yükünün 50% ile %100’ ünde test edilir.<br />
(Deney yükü hiç bir zaman 1VA’ den küçük olamaz)</p>
<p>Kaynak Alce</p>
<p><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 728x15, oluşturulma 20.11.2008 */
google_ad_slot = "6035974834";
google_ad_width = 728;
google_ad_height = 15;
//-->
</script>
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p> ]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-akim-transformatorlerinde-akim-yanilgisi-ve-faz-kaymasi-hatalari-tip-testleri-209.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Akım Transformatörleri İçin Ek Veriler</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/akim-transformatorleri-icin-ek-veriler-199.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/akim-transformatorleri-icin-ek-veriler-199.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 23:34:52 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Akım Gerilim Trafoları]]></category>
		<category><![CDATA[60Hz]]></category>
		<category><![CDATA[AG/OG]]></category>
		<category><![CDATA[Akım Hatası]]></category>
		<category><![CDATA[Akım transformatörleri]]></category>
		<category><![CDATA[Faz Kayması]]></category>
		<category><![CDATA[Ölçü Akım]]></category>
		<category><![CDATA[şebeke kirliliği]]></category>
		<category><![CDATA[Transformatörlerinde]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=199</guid>
		<description><![CDATA[Ölçü Akım Transformatörlerinde Sınıflandırılma Tasarımı Akım transformatörleri en yüksek izin verilen yüzde akım yanılgısı, nominal anma akımı ve onunla ilgili sınıfı içinde tasarımlanır Standard Doğruluk Sınıfları IEC 60044-1/1996-12 – Clause 11.1.1 Ölçü akım transformatörleri için bu değerler aşağıdaki gibi tanımlanmıştır. 0.1 – 0.2 – 0.5 – 1.0 – 3.0 – 5.0 Ölçü Akım Transformatörlerinde Akım [...]]]></description>
			<content:encoded><![CDATA[<p>Ölçü Akım Transformatörlerinde Sınıflandırılma Tasarımı Akım transformatörleri en yüksek izin verilen yüzde akım yanılgısı, nominal anma akımı ve onunla ilgili sınıfı içinde tasarımlanır<span id="more-199"></span><br />
<strong>Standard Doğruluk Sınıfları</strong><br />
IEC 60044-1/1996-12 – Clause 11.1.1<br />
Ölçü akım transformatörleri için bu değerler aşağıdaki gibi tanımlanmıştır.<br />
0.1 – 0.2 – 0.5 – 1.0 – 3.0 – 5.0<br />
<strong>Ölçü Akım Transformatörlerinde Akım Hatası ve Faz Kayması</strong><br />
IEC 60044-1/1996-12 – Clause 11.2<br />
Doğruluk sınıfı, 0.1 – 0.2 – 0.5 – 1.0 olan akım transformatörlerinde, anma frekansında<br />
akım yanılgısı ve faz kayması, sekonder anma yükünün %25’ i ve %100’ ünde iken<br />
Tablo 8’ de verilen değerleri aşmamalıdır.<br />
<div id="attachment_200" class="wp-caption alignnone" style="width: 610px"><img src="http://www.indiriniz.com/wp-content/uploads/2009/03/adsiz-19.jpg" alt="Tablo 8" title="adsiz-19" width="600" height="180" class="size-full wp-image-200" /><p class="wp-caption-text">Tablo 8</p></div></p>
<p>0.2S ve 0.5S sınıfları olarak tanımlanan ve özel kullanımlarda 50mA….6A arası, yani anma<br />
akımının %1’ i ile %120’ si olarak sekonder anma akımı 5A olan ölçü transformatörlerinin<br />
anma frekansında ve anma yükünün %25’ i ile %100’ ünde akım yanılgısı ve faz kayması<br />
değerleri Tablo 9’ da verilen değerleri aşmamalıdır.</p>
<div id="attachment_202" class="wp-caption alignnone" style="width: 610px"><img src="http://www.indiriniz.com/wp-content/uploads/2009/03/adsiz-20.jpg" alt="Tablo 9" title="adsiz-20" width="600" height="121" class="size-full wp-image-202" /><p class="wp-caption-text">Tablo 9</p></div><br />
Bu tür akım transformatörleri, genelde 25/5A, 50/5A ve 100/5A veya bunların desimal<br />
çarpımlarınıda kapsayan primer akımlarına sahip ve sadece sekonder akımları 5A olan<br />
ölçü akım transformatörleri için tanımlanmıştır.<br />
Doğruluk sınıfı 3.0 ve 5.0 olan akım transformatörleri, anma frekansında akım yanılgısı<br />
sekonder yük anma yükünün %50 ile %100’ ü arasında iken, Tablo 10’ da verilen<br />
değerleri aşmamalıdır.<br />
3.0 ve 5.0 Sınıfı ölçü transformatörleri için faz kayması açı sınırları istenmemektedir.</p>
<p>Ölçü akım transformatörlerinin deneylerinde kullanılan sekonder yükün değeri 5VA’ e eşit veya daha büyük olduğunda güç katsayısı 0.8 endüktif olmalı; yük 5VA’ den küçük olduğunda güç katsayısı 1’ e eşit olmalıdır. Deney yükü hiç bir zaman 1VA’ den küçük olmamalıdır.<br />
<div id="attachment_205" class="wp-caption alignnone" style="width: 232px"><img src="http://www.indiriniz.com/wp-content/uploads/2009/03/adsiz-21.jpg" alt="Tablo 10" title="adsiz-21" width="222" height="174" class="size-full wp-image-205" /><p class="wp-caption-text">Tablo 10</p></div>
<p>Kaynak Alce</p>
<p><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 728x15, oluşturulma 20.11.2008 */
google_ad_slot = "6035974834";
google_ad_width = 728;
google_ad_height = 15;
//-->
</script>
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p> ]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/akim-transformatorleri-icin-ek-veriler-199.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

