<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>indiriniz.com &#187; kondansatÃ¶r</title>
	<atom:link href="http://www.indiriniz.com/kompanzasyon/kondansator/feed" rel="self" type="application/rss+xml" />
	<link>http://www.indiriniz.com</link>
	<description>Kompanzasyon Enerji kalitesi GÃ¼nlÃ¼ÄŸÃ¼</description>
	<lastBuildDate>Thu, 14 May 2009 13:51:35 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.8.4</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>Anma Ã‡Ä±kÄ±ÅŸ GÃ¼cÃ¼</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/anma-cikis-gucu-284.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/anma-cikis-gucu-284.html#comments</comments>
		<pubDate>Tue, 14 Apr 2009 02:31:43 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[AkÄ±m Gerilim TrafolarÄ±]]></category>
		<category><![CDATA[Anma Ã‡Ä±kÄ±ÅŸ GÃ¼cÃ¼]]></category>
		<category><![CDATA[Gerilim TransformatÃ¶rleri]]></category>
		<category><![CDATA[gÃ¶rÃ¼nÃ¼r gÃ¼c]]></category>
		<category><![CDATA[kondansatÃ¶r]]></category>
		<category><![CDATA[primary winding]]></category>
		<category><![CDATA[rated output burden]]></category>
		<category><![CDATA[volt-amper]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=284</guid>
		<description><![CDATA[Anma Ã‡Ä±kÄ±ÅŸ GÃ¼cÃ¼ rated output burden 
Gerilim transformatÃ¶rÃ¼, sekonder anma geriliminde anma yÃ¼kÃ¼ne
baÄŸlandÄ±ÄŸÄ±nda, bu transformatÃ¶rÃ¼n, sekonder devrede, yanÄ±lgÄ±lar
belirlenmiÅŸ deÄŸerleri aÅŸmadan verdiÄŸi ve belirli bir gÃ¼Ã§ katsayÄ±sÄ±nda
volt-amper cinsinden ifade edilen gÃ¶rÃ¼nÃ¼r gÃ¼Ã§tÃ¼r.






IEC 60044-2/1997-02 â€“ Clause 2.1.17.1



 ]]></description>
			<content:encoded><![CDATA[<p>Anma Ã‡Ä±kÄ±ÅŸ GÃ¼cÃ¼ <strong>rated output burden </strong><br />
Gerilim transformatÃ¶rÃ¼, sekonder anma geriliminde anma yÃ¼kÃ¼ne<br />
baÄŸlandÄ±ÄŸÄ±nda, bu transformatÃ¶rÃ¼n, sekonder devrede, yanÄ±lgÄ±lar<br />
belirlenmiÅŸ deÄŸerleri aÅŸmadan verdiÄŸi ve belirli bir gÃ¼Ã§ katsayÄ±sÄ±nda<br />
volt-amper cinsinden ifade edilen gÃ¶rÃ¼nÃ¼r gÃ¼Ã§tÃ¼r.<span id="more-284"></span><br /><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p>
<p>IEC 60044-2/1997-02 â€“ Clause 2.1.17.1</p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/anma-cikis-gucu-284.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>GeniÅŸletilmiÅŸ Ã–lÃ§Ã¼ AkÄ±m TransformatÃ¶rleri Ã–lÃ§me SahalarÄ±</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/genisletilmis-olcu-akim-transformatorleri-olcme-sahalari-207.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/genisletilmis-olcu-akim-transformatorleri-olcme-sahalari-207.html#comments</comments>
		<pubDate>Mon, 30 Mar 2009 20:02:08 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[AkÄ±m Gerilim TrafolarÄ±]]></category>
		<category><![CDATA[AkÄ±m HatasÄ±]]></category>
		<category><![CDATA[AkÄ±m transformatÃ¶rleri]]></category>
		<category><![CDATA[endÃ¼stri]]></category>
		<category><![CDATA[Harmonik]]></category>
		<category><![CDATA[kablo]]></category>
		<category><![CDATA[kompanzasyon trafosu]]></category>
		<category><![CDATA[kondansatÃ¶r]]></category>
		<category><![CDATA[Ã–lÃ§me SahalarÄ±]]></category>
		<category><![CDATA[Ã¶lÃ§Ã¼]]></category>
		<category><![CDATA[Ã¶lÃ§Ã¼ transformatÃ¶rleri]]></category>
		<category><![CDATA[Ã–zel testler]]></category>
		<category><![CDATA[TopraklanmÄ±ÅŸ Åžebeke]]></category>
		<category><![CDATA[transformatÃ¶r]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=207</guid>
		<description><![CDATA[Ã–lÃ§Ã¼ akÄ±m transformatÃ¶rleri 0.1 ile 1.0 doÄŸruluk sÄ±nÄ±flarÄ± iÃ§erisinde, aÅŸaÄŸÄ±daki ÅŸartÄ±
yerine getirmek koÅŸuluyla, geniÅŸletilmiÅŸ akÄ±m Ã¶lÃ§me sahasÄ± iÃ§in markalanabilirler.






- AkÄ±m transformatÃ¶rÃ¼nÃ¼n sÃ¼rekli termik akÄ±mÄ±, primer anma akÄ±mÄ±nÄ±n yÃ¼zde olarak
geniÅŸletilmiÅŸi olarak tarif edilmesi halinde,
akÄ±m yanÄ±lgÄ±sÄ± ve faz kaymasÄ± deÄŸerleri, Tablo 8
â€™ de primer akÄ±mÄ±n %120 primer
akÄ±mÄ± iÃ§in verilen sÄ±nÄ±r deÄŸerleri aÅŸmamalÄ±dÄ±r.
Standard primer akÄ±m geniÅŸleme sahalarÄ±, primer [...]]]></description>
			<content:encoded><![CDATA[<p>Ã–lÃ§Ã¼ akÄ±m transformatÃ¶rleri 0.1 ile 1.0 doÄŸruluk sÄ±nÄ±flarÄ± iÃ§erisinde, aÅŸaÄŸÄ±daki ÅŸartÄ±<br />
yerine getirmek koÅŸuluyla, geniÅŸletilmiÅŸ akÄ±m Ã¶lÃ§me sahasÄ± iÃ§in markalanabilirler.<span id="more-207"></span><br /><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p>
<p>- AkÄ±m transformatÃ¶rÃ¼nÃ¼n sÃ¼rekli termik akÄ±mÄ±, primer anma akÄ±mÄ±nÄ±n yÃ¼zde olarak<br />
geniÅŸletilmiÅŸi olarak tarif edilmesi halinde,<br />
akÄ±m yanÄ±lgÄ±sÄ± ve faz kaymasÄ± deÄŸerleri, Tablo 8<br />
â€™ de primer akÄ±mÄ±n %120 primer<br />
akÄ±mÄ± iÃ§in verilen sÄ±nÄ±r deÄŸerleri aÅŸmamalÄ±dÄ±r.<br />
Standard primer akÄ±m geniÅŸleme sahalarÄ±, primer nominal akÄ±mÄ±n yÃ¼zdesi olarak,<br />
120% &#8211; 150% &#8211; 200%<br />
ÅŸeklinde tarif edilmiÅŸtir.<br />
Not:<br />
TS 620/1978 Paragraf 1.2.2.3bâ€™ ye bakÄ±nÄ±z.<br />
IEC 60044-1/1996-12 â€“ Clause 11.3</p>
<p><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 728x15, oluÅŸturulma 20.11.2008 */
google_ad_slot = "6035974834";
google_ad_width = 728;
google_ad_height = 15;
//-->
</script>
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p> ]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/genisletilmis-olcu-akim-transformatorleri-olcme-sahalari-207.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Gerilim TransformatÃ¶rleri</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/gerilim-transformatorleri-152.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/gerilim-transformatorleri-152.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 21:37:44 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[AkÄ±m Gerilim TrafolarÄ±]]></category>
		<category><![CDATA[AkÄ±m transformatÃ¶rleri]]></category>
		<category><![CDATA[AkÄ±mlar]]></category>
		<category><![CDATA[Gerilim TransformatÃ¶rleri]]></category>
		<category><![CDATA[Kompanzasyon]]></category>
		<category><![CDATA[kondansatÃ¶r]]></category>
		<category><![CDATA[Ã¶lÃ§Ã¼ transformatÃ¶rleri]]></category>
		<category><![CDATA[ÅŸebeke]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=152</guid>
		<description><![CDATA[BaÅŸkaca belirtilmedikÃ§e, ortam sÄ±caklÄ±ÄŸÄ±na gÃ¶re sÄ±nÄ±flandÄ±rÄ±lmada aÃ§Ä±klanan iÅŸletme
koÅŸullarÄ±nda Ã§alÄ±ÅŸtÄ±rÄ±lan bir gerilim transformatÃ¶rÃ¼nde sÄ±caklÄ±k artÄ±ÅŸlarÄ±, anma






gerilim yÃ¼kseltme katsayÄ±sÄ± ve buna karÅŸÄ±lÄ±k olan gerilim uygulama sÃ¼resi ne olursa
olsun, belirli bir gerilimde ve anma frekansÄ±nda, anma yÃ¼kÃ¼nde veya bu yÃ¼klerin
birden Ã§ok olmasÄ± halinde bunlarÄ±n en bÃ¼yÃ¼ÄŸÃ¼ne eÅŸit bir yÃ¼kte ve 0.8 â€“ 1 arasÄ±nda
bulunan bir gÃ¼Ã§ katsayÄ±sÄ±nda, Tablo [...]]]></description>
			<content:encoded><![CDATA[<p>BaÅŸkaca belirtilmedikÃ§e, ortam sÄ±caklÄ±ÄŸÄ±na gÃ¶re sÄ±nÄ±flandÄ±rÄ±lmada aÃ§Ä±klanan iÅŸletme<br />
koÅŸullarÄ±nda Ã§alÄ±ÅŸtÄ±rÄ±lan bir gerilim transformatÃ¶rÃ¼nde sÄ±caklÄ±k artÄ±ÅŸlarÄ±, anma<span id="more-152"></span><br /><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p>
<p>gerilim yÃ¼kseltme katsayÄ±sÄ± ve buna karÅŸÄ±lÄ±k olan gerilim uygulama sÃ¼resi ne olursa<br />
olsun, belirli bir gerilimde ve anma frekansÄ±nda, anma yÃ¼kÃ¼nde veya bu yÃ¼klerin<br />
birden Ã§ok olmasÄ± halinde bunlarÄ±n en bÃ¼yÃ¼ÄŸÃ¼ne eÅŸit bir yÃ¼kte ve 0.8 â€“ 1 arasÄ±nda<br />
bulunan bir gÃ¼Ã§ katsayÄ±sÄ±nda, Tablo 5â€˜ de gÃ¶sterilen sÄ±nÄ±rlarÄ± aÅŸmamalÄ±dÄ±r.<br />
(Bu Ã¶zellik bÃ¼tÃ¼n gerilim transformatÃ¶rleri iÃ§in geÃ§erlidir).<br />
SÄ±caklÄ±k artÄ±ÅŸ deneyinde gerilim transformatÃ¶rÃ¼ne uygulanan gerilimler aÅŸaÄŸÄ±daki<br />
gibi olmalÄ±dÄ±r:<br />
- Anma gerilim yÃ¼kseltme katsayÄ±sÄ± ve buna karÅŸÄ±lÄ±k olan gerilim uygulanma sÃ¼resi<br />
ne olursa olsun, bÃ¼tÃ¼n gerilim transformatÃ¶rlerine primer anma geriliminin<br />
1.2 katÄ±na eÅŸit bir gerilim uygulanmalÄ±, deneye transformatÃ¶r kararlÄ± sÄ±caklÄ±ÄŸa<br />
eriÅŸinceye kadar devam edilmeli ve deneyin sonunda Tablo 5â€™ de gÃ¶sterilen<br />
deÄŸerlerin saÄŸlanÄ±p saÄŸlanamadÄ±ÄŸÄ±na bakÄ±lmalÄ±dÄ±r.<br />
- Anma gerilim yÃ¼kseltme katsayÄ±sÄ± 30 saniye iÃ§in 1.5 veya 30 saniye iÃ§in 1.9 olan<br />
gerilim transformatÃ¶rlerine, primer anma geriliminin 1.2 katÄ±na eÅŸit bir gerilim,<br />
transformatÃ¶r kararlÄ± sÄ±caklÄ±ÄŸa eriÅŸinceye kadar uygulanmalÄ±; bundan sonra, anma<br />
gerilim yÃ¼kselme katsayÄ±sÄ±na karÅŸÄ±lÄ±k olan gerilim 30 saniye sÃ¼re ile uygulanmalÄ±<br />
ve deneyin sonunda sÄ±caklÄ±k artÄ±ÅŸÄ± Tablo 5â€™ de gÃ¶sterilen deÄŸeri 10Â°Câ€™ den Ã§ok<br />
aÅŸmamalÄ±dÄ±r.<br />
Bu gerilim transformatÃ¶rÃ¼nde sÄ±caklÄ±k artÄ±ÅŸÄ±, deney transformatÃ¶r soÄŸuk durumda<br />
iken baÅŸlanmak ve anma gerilim yÃ¼kseltma katsayÄ±sÄ±na karÅŸÄ±lÄ±k olan gerilim<br />
30 saniye sÃ¼re ile uygulanmak sureti ile de yapÄ±labilir. Bu koÅŸullarda yapÄ±lan<br />
deneyin sonucunda, gerilim transformatÃ¶rÃ¼nÃ¼n sÄ±caklÄ±k artÄ±ÅŸÄ±, baÅŸlangÄ±Ã§taki<br />
sÄ±caklÄ±ÄŸa gÃ¶re 10Â°Câ€™ yi geÃ§memelidir.<br />
- Anma gerilim yÃ¼kseltme katsayÄ±sÄ± 8 saat iÃ§in 1.9 olan gerilim transformatÃ¶rlerine,<br />
primer anma geriliminin 1.2 katÄ±na eÅŸit bir gerilim, transformatÃ¶r kararlÄ± sÄ±caklÄ±ÄŸa<br />
eriÅŸinceye kadar uygulanmalÄ±; bundan sonra anma gerilim yÃ¼kseltme katsayÄ±sÄ±na<br />
karÅŸÄ±lÄ±k olan gerilim 8 saat sÃ¼re ile uygulanmalÄ± ve deneyin sonunda<br />
transformatÃ¶rdeki sÄ±caklÄ±k artÄ±ÅŸÄ± Tablo 5â€™ de verilen deÄŸerleri 10Â°Câ€™ den Ã§ok<br />
aÅŸmamalÄ±dÄ±r.<br />
EÄŸer transformatÃ¶r sargÄ±larÄ± termik yÃ¼k deÄŸerli ise, bu transformatÃ¶r primer anma<br />
geriliminde ve yÃ¼kÃ¼ bu termik yÃ¼ke eÅŸit empedans ve gÃ¼Ã§ faktÃ¶rlÃ¼ yÃ¼klenmiÅŸ ancak,<br />
aÃ§Ä±k Ã¼Ã§gen sargÄ±sÄ± yÃ¼ksÃ¼z olarak tekrar test edilir.<br />
Gerilim transformatÃ¶rÃ¼nde yÃ¼kÃ¼ sipesifik olan birden fazla se<br />
konder sargÄ±nÄ±n<br />
bulunmasÄ± durumunda sÄ±caklÄ±k artÄ±ÅŸÄ± deneyi, bu termik yÃ¼kle yÃ¼klÃ¼ ve yÃ¼kÃ¼n<br />
anma gÃ¼Ã§ katsayÄ±sÄ±nda yÃ¼klenerek her bir sargÄ± iÃ§in ayrÄ± ayrÄ± yapÄ±lÄ±r.<br />
Test sargÄ± sÄ±caklÄ±klarÄ± kararlÄ± sÄ±caklÄ±ÄŸa eriÅŸinceye kadar ( en son iki Ã¶lÃ§Ã¼m arasÄ±<br />
sÄ±caklÄ±k farkÄ± 1Â°Câ€™ ye eÅŸit veya kÃ¼Ã§Ã¼k olduÄŸunda) devam eder.<br />
Bu tÃ¼r bir transformatÃ¶re ait Ã¶rnek test adÄ±mlarÄ± Tablo 6â€™ da verilmiÅŸtir.</p>
<p>Gerilim TransformatÃ¶rleri (IEC 60044-2/1997â€“02 Clause 5.4)</p>
<p><img class="alignnone size-full wp-image-153" title="adsiz-7" src="http://www.indiriniz.com/wp-content/uploads/2009/03/adsiz-7.jpg" alt="adsiz-7" width="600" height="400" /></p>
<p>Tablo 6.. Tek kutuplu artÄ±k gerilim sargÄ±lÄ± bir gerilim transformatÃ¶rÃ¼ne ait, Ã¶rnek test adÄ±mlarÄ±.<br />
- Deniz seviyesine gÃ¶re 1000mâ€™ nin Ã¼zerinde bulunan bir yÃ¼kseltide Ã§alÄ±ÅŸmasÄ± Ã¶ngÃ¶rÃ¼len,<br />
ancak deneyleri 1000mâ€™ nin altÄ±nda yapÄ±lan Ã¶lÃ§Ã¼ transformatÃ¶rlerinin sÄ±caklÄ±k artÄ±ÅŸ<br />
sÄ±nÄ±rlarÄ± Ã§alÄ±ÅŸma yerinin 1000mâ€™ nin Ã¼zerindeki her 100m yÃ¼ksekliÄŸi iÃ§in,<br />
- yaÄŸlÄ± Ã¶lÃ§Ã¼ transformatÃ¶rlerinde % 0.4<br />
- kuru Ã¶lÃ§Ã¼ transformatÃ¶rlerinde % 0.5<br />
oranÄ±nda kÃ¼Ã§Ã¼ltÃ¼lmelidir.<br />
- SargÄ±larÄ±n sÄ±caklÄ±k artÄ±ÅŸlarÄ±, sargÄ±nÄ±n kendi yalÄ±tkanÄ±nÄ±n, iÃ§ine daldÄ±rÄ±lmÄ±ÅŸ bulunduÄŸu<br />
yalÄ±tkan ortamÄ±n en dÃ¼ÅŸÃ¼k yalÄ±tÄ±m seviyesi ile sÄ±nÄ±rlanmÄ±ÅŸtÄ±r.<br />
YalÄ±tkanlar iÃ§in sÄ±nÄ±flarÄ±na gÃ¶re kabul edilebilecek sÄ±caklÄ±k artÄ±ÅŸÄ± sÄ±nÄ±rlarÄ± Tablo 5â€™ de<br />
gÃ¶sterilmiÅŸtir.<br />
- Ã–lÃ§Ã¼ transformatÃ¶rÃ¼ bir yaÄŸ genleÅŸme kabÄ± ile donatÄ±lmÄ±ÅŸsa ve yaÄŸÄ±n Ã¼zerinde asal bir<br />
gaz bulunuyorsa veya,<br />
rt<br />
TestNoAÅŸÄ±rÄ± GerilimDeneySekonder SargÄ±AÃ§Ä±k ÃœÃ§gen SargÄ±Ã–lÃ§me NoktalarÄ±SÄ±caklÄ±k FaktÃ¶rÃ¼SÃ¼resiCosb=0.8Cosb=0.8AÄ±ÅŸÄ± Â°C11.2 UnSÄ±caklÄ±k artÄ±ÅŸÄ±max.klasgÃ¼cÃ¼YÃ¼ksÃ¼zPrimerSargÄ±13.4sabit olana kadar150VASekonderSargÄ±17.5AÃ§Ä±k ÃœÃ§gen SargÄ±13.521.0 UnSÄ±caklÄ±k artÄ±ÅŸÄ±Termik YÃ¼kYÃ¼ksÃ¼zPrimerSargÄ±22.1sabit olana kadar350VASekonderSargÄ±28.0AÃ§Ä±k ÃœÃ§gen SargÄ±22.531.9 Un8hmax.klasgÃ¼cÃ¼Termik YÃ¼kPrimerSargÄ±28.4150VA400VASekonderSargÄ±38.6AÃ§Ä±k ÃœÃ§gen SargÄ±40.5<br />
- Ã–lÃ§Ã¼ transformatÃ¶rÃ¼ hava sÄ±zdÄ±rmayacak (hermetik) biÃ§imde kapalÄ± ise, kazanÄ±n Ã¼st<br />
kÄ±smÄ±ndaki yaÄŸÄ±n sÄ±caklÄ±k artÄ±ÅŸÄ± 55Â°Câ€™ yi aÅŸmamalÄ±dÄ±r.<br />
YukarÄ±daki dÃ¼zenlerin hiÃ§birinin bulunmadÄ±ÄŸÄ± durumlarda, kazanÄ±n Ã¼st kÄ±smÄ±ndaki yaÄŸÄ±n<br />
sÄ±caklÄ±k artÄ±ÅŸÄ± 50Â°Câ€™ yi aÅŸmamalÄ±dÄ±r.<br />
SargÄ±larla veya yalÄ±tkanlarla temasta olan veya bunlarÄ±n Ã§ok yakÄ±nÄ±nda bulunan manyetik<br />
devrenin ve diÄŸer metal kÄ±sÄ±mlarÄ±nÄ±n yÃ¼zeylerinde Ã¶lÃ§Ã¼len sÄ±caklÄ±k artÄ±ÅŸlarÄ±, sargÄ±lar veya<br />
yalÄ±tkanlar iÃ§in Tablo 5â€™ de verilen deÄŸerleri aÅŸmamalÄ±dÄ±r.</p>
<p>Kaynak: Alce Elektrik</p>
<p><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 728x15, oluÅŸturulma 20.11.2008 */
google_ad_slot = "6035974834";
google_ad_width = 728;
google_ad_height = 15;
//-->
</script>
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p> ]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/gerilim-transformatorleri-152.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>SÃ¶ndÃ¼rme Bobini Ãœzerinden TopraklanmÄ±ÅŸ Åžebeke</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/sondurme-bobini-uzerinden-topraklanmis-sebeke-134.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/sondurme-bobini-uzerinden-topraklanmis-sebeke-134.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 21:03:21 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[AkÄ±m Gerilim TrafolarÄ±]]></category>
		<category><![CDATA[50Hz]]></category>
		<category><![CDATA[AkÄ±m transformatÃ¶rleri]]></category>
		<category><![CDATA[Gerilim TransformatÃ¶rleri]]></category>
		<category><![CDATA[Harmonik]]></category>
		<category><![CDATA[Kompanzasyon]]></category>
		<category><![CDATA[kondansatÃ¶r]]></category>
		<category><![CDATA[Ã¶lÃ§Ã¼ transformatÃ¶rleri]]></category>
		<category><![CDATA[ÅŸebeke]]></category>
		<category><![CDATA[SÃ¶ndÃ¼rme Bobini]]></category>
		<category><![CDATA[topraklama]]></category>
		<category><![CDATA[TopraklanmÄ±ÅŸ Åžebeke]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=134</guid>
		<description><![CDATA[Faz ile toprak arasÄ±nda bir arÄ±za oluÅŸtuÄŸunda, arÄ±za akÄ±mÄ±nÄ±n ÅŸebeke frekanslÄ± kapasitif
bileÅŸenini, pratik olarak etkisiz hale getirecek deÄŸerde bir ÅŸebeke frekanslÄ± endÃ¼ktif






akÄ±mÄ±n toprak ile bobin arasÄ±nda dolaÅŸmasÄ±nÄ± saÄŸlayacak deÄŸerde reaktansÄ± olan bir
bobin aracÄ±lÄ±ÄŸÄ±yla, nÃ¶trÃ¼ topraÄŸa baÄŸlanmÄ±ÅŸ olan ÅŸebekedir.
Not:
SÃ¶ndÃ¼rme bobini Ã¼zerinden topraklamÄ±ÅŸ ÅŸebekede arÄ±za artÄ±k akÄ±mÄ±, havadaki arÄ±za
arkÄ±nÄ±n kendiliÄŸinden sÃ¶nmesini saÄŸlayacak deÄŸerde sÄ±nÄ±rlandÄ±rÄ±lmÄ±ÅŸtÄ±r.
AkÄ±m TransformatÃ¶rleri (IEC 60044-1/1996-12 [...]]]></description>
			<content:encoded><![CDATA[<p>Faz ile toprak arasÄ±nda bir arÄ±za oluÅŸtuÄŸunda, arÄ±za akÄ±mÄ±nÄ±n ÅŸebeke frekanslÄ± kapasitif<br />
bileÅŸenini, pratik olarak etkisiz hale getirecek deÄŸerde bir ÅŸebeke frekanslÄ± endÃ¼ktif<span id="more-134"></span><br /><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p>
<p>akÄ±mÄ±n toprak ile bobin arasÄ±nda dolaÅŸmasÄ±nÄ± saÄŸlayacak deÄŸerde reaktansÄ± olan bir<br />
bobin aracÄ±lÄ±ÄŸÄ±yla, nÃ¶trÃ¼ topraÄŸa baÄŸlanmÄ±ÅŸ olan ÅŸebekedir.<br />
Not:<br />
SÃ¶ndÃ¼rme bobini Ã¼zerinden topraklamÄ±ÅŸ ÅŸebekede arÄ±za artÄ±k akÄ±mÄ±, havadaki arÄ±za<br />
arkÄ±nÄ±n kendiliÄŸinden sÃ¶nmesini saÄŸlayacak deÄŸerde sÄ±nÄ±rlandÄ±rÄ±lmÄ±ÅŸtÄ±r.</p>
<p>AkÄ±m TransformatÃ¶rleri (IEC 60044-1/1996-12 â€“ Clause 2.1.21)<br />
Gerilim TransformatÃ¶rleri (IEC 60044-2/1997-02 â€“ Clause 2.1.22)</p>
<p>kaynak: Alce Elektrik</p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/sondurme-bobini-uzerinden-topraklanmis-sebeke-134.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Harmonik Nedir</title>
		<link>http://www.indiriniz.com/harmonik/harmonik-nedir-2-98.html</link>
		<comments>http://www.indiriniz.com/harmonik/harmonik-nedir-2-98.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 16:25:54 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Harmonik]]></category>
		<category><![CDATA[endÃ¼ksiyon]]></category>
		<category><![CDATA[kondansatÃ¶r]]></category>
		<category><![CDATA[tristÃ¶r]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/wp/?p=98</guid>
		<description><![CDATA[GÃ¼Ã§ sistemlerinde ideal koÅŸullarda alternatif akÄ±mÄ±n dalga biÃ§imi sinÃ¼s eÄŸrisi ÅŸeklinde olmalÄ±dÄ±r, fakat pratikte bu tÃ¼r eÄŸri ÅŸekli ile Ã§alÄ±ÅŸmak pek mÃ¼mkÃ¼n olmamaktadÄ±r. 






Åžekil-1â€™de gÃ¶rÃ¼ldÃ¼ÄŸÃ¼ gibi eÄŸride bir takÄ±m bozulmalar oluÅŸmaktadÄ±r.

Åžekil-1
SinÃ¼soidal ÅŸekildeki bu bozulmalar istenilen bir durum deÄŸildir. Bu tÃ¼r iÅŸaretlerle Ã§alÄ±ÅŸan elemanlarda ya da yÃ¼klerde fazladan gÃ¼Ã§ kaybÄ± (distorsiyon gÃ¼cÃ¼) ve arÄ±zalar meydana gelir. [...]]]></description>
			<content:encoded><![CDATA[<p>GÃ¼Ã§ sistemlerinde ideal koÅŸullarda alternatif akÄ±mÄ±n dalga biÃ§imi sinÃ¼s eÄŸrisi ÅŸeklinde olmalÄ±dÄ±r, fakat pratikte bu tÃ¼r eÄŸri ÅŸekli ile Ã§alÄ±ÅŸmak pek mÃ¼mkÃ¼n olmamaktadÄ±r. <span id="more-98"></span><br /><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><br />
Åžekil-1â€™de gÃ¶rÃ¼ldÃ¼ÄŸÃ¼ gibi eÄŸride bir takÄ±m bozulmalar oluÅŸmaktadÄ±r.</p>
<p><img src="../../rsm/harmonik_1.jpg" border="0" alt="" /><br />
Åžekil-1</p>
<p>SinÃ¼soidal ÅŸekildeki bu bozulmalar istenilen bir durum deÄŸildir. Bu tÃ¼r iÅŸaretlerle Ã§alÄ±ÅŸan elemanlarda ya da yÃ¼klerde fazladan gÃ¼Ã§ kaybÄ± (distorsiyon gÃ¼cÃ¼) ve arÄ±zalar meydana gelir. Bu durum alternatif akÄ±mÄ±n kullanÄ±ldÄ±ÄŸÄ± ilk gÃ¼nlerden bu yana varolmuÅŸtur. Bilim adamlarÄ± sinÃ¼soidal ÅŸekildeki bozulmalarÄ± belirli sÄ±nÄ±rlar iÃ§inde tutmak veya tamamen yok etmek iÃ§in Ã§Ã¶zÃ¼mler aramÄ±ÅŸlardÄ±r.</p>
<p><img src="../../rsm/harmonik_2.jpg" border="0" alt="" /><br />
Åžekil-2</p>
<p>FransÄ±z fizikÃ§isi ve matematikÃ§isi Joseph Fourier 1882 yÄ±lÄ±nda Ã§Ã¶zÃ¼m olabilecek bir teori geliÅŸtirmiÅŸtir. Teoriyi sadece alternatif akÄ±m iÃ§in kÄ±saca ele alacak olursak, sinÃ¼soidal ÅŸekildeki bozulmanÄ±n sebebi, ana frekansÄ±n tam katlarÄ± olan frekanslara sahip sinÃ¼soidal bileÅŸenlerdir. Bu bileÅŸenlerin her birine harmonik denir. SinÃ¼s eÄŸrisindeki harmoniklerin sebebi, gÃ¼Ã§ sistemlerinde farklÄ± amaÃ§larla kullanÄ±lan bazÄ± cihaz ve devrelerdir. Harmonik oluÅŸturan kaynaklar bÃ¶lÃ¼m 2â€™de detaylÄ± olarak incelenecektir.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/harmonik/harmonik-nedir-2-98.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Harmonik oluÅŸmasÄ±na sebep olan cihazlar</title>
		<link>http://www.indiriniz.com/harmonik/harmonik-olusmasina-sebep-olan-cihazlar-96.html</link>
		<comments>http://www.indiriniz.com/harmonik/harmonik-olusmasina-sebep-olan-cihazlar-96.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 16:24:12 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Harmonik]]></category>
		<category><![CDATA[endÃ¼ksiyon]]></category>
		<category><![CDATA[kondansatÃ¶r]]></category>
		<category><![CDATA[trafo]]></category>
		<category><![CDATA[tristÃ¶r]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/wp/?p=96</guid>
		<description><![CDATA[DoÄŸrusal olmayan yÃ¼kler olarak adlandÄ±rÄ±lan yÃ¼kler harmonik oluÅŸlmasÄ±na sebep olurlar:







elektronik hÄ±z kontrol cihazlarÄ±
ark fÄ±rÄ±nlarÄ±
tristÃ¶r kontrollÃ¼ doÄŸrultucular (redresÃ¶rler)
kaynak makinalarÄ±
statik konvertÃ¶rler (UPS)
floresan lambalar, v.b.

]]></description>
			<content:encoded><![CDATA[<p>DoÄŸrusal olmayan yÃ¼kler olarak adlandÄ±rÄ±lan yÃ¼kler harmonik oluÅŸlmasÄ±na sebep olurlar:<span id="more-96"></span><br /><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p>
<ol>
<li><strong>elektronik hÄ±z kontrol cihazlarÄ±</strong></li>
<li><strong>ark fÄ±rÄ±nlarÄ±</strong></li>
<li><strong>tristÃ¶r kontrollÃ¼ doÄŸrultucular (redresÃ¶rler)</strong></li>
<li><strong>kaynak makinalarÄ±</strong></li>
<li><strong>statik konvertÃ¶rler (UPS)</strong></li>
<li><strong>floresan lambalar, v.b.</strong></li>
</ol>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/harmonik/harmonik-olusmasina-sebep-olan-cihazlar-96.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>EndÃ¼striyel Åžebekelerde harmonikler</title>
		<link>http://www.indiriniz.com/harmonik/endustriyel-sebekelerde-harmonikler-94.html</link>
		<comments>http://www.indiriniz.com/harmonik/endustriyel-sebekelerde-harmonikler-94.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 16:22:23 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Harmonik]]></category>
		<category><![CDATA[kondansatÃ¶r]]></category>
		<category><![CDATA[trafo]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/wp/?p=94</guid>
		<description><![CDATA[GÃ¼nÃ¼mÃ¼zde endÃ¼striyel sektÃ¶rde gÃ¼Ã§ elektroniÄŸi devreleri iÃ§eren elektrik cihazlarÄ±nÄ±n
kullanÄ±mÄ± hÄ±zla artmaktadÄ±r. Bu cihazlar akÄ±mÄ±n dalga Åžeklinin bozulmasÄ±na dolayÄ±sÄ±yla






harmoniklerin Ã¼retilmesine yol aÃ§arlar ve elektrik Åžebekesini kirletirler.
]]></description>
			<content:encoded><![CDATA[<p>GÃ¼nÃ¼mÃ¼zde endÃ¼striyel sektÃ¶rde gÃ¼Ã§ elektroniÄŸi devreleri iÃ§eren elektrik cihazlarÄ±nÄ±n<br />
kullanÄ±mÄ± hÄ±zla artmaktadÄ±r. Bu cihazlar akÄ±mÄ±n dalga Åžeklinin bozulmasÄ±na dolayÄ±sÄ±yla<span id="more-94"></span><br /><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p>
<p>harmoniklerin Ã¼retilmesine yol aÃ§arlar ve elektrik Åžebekesini kirletirler.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/harmonik/endustriyel-sebekelerde-harmonikler-94.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Harmonik dalga oluÅŸlumu</title>
		<link>http://www.indiriniz.com/harmonik/harmonik-dalga-oluslumu-92.html</link>
		<comments>http://www.indiriniz.com/harmonik/harmonik-dalga-oluslumu-92.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 16:20:26 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Harmonik]]></category>
		<category><![CDATA[kondansatÃ¶r]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/wp/?p=92</guid>
		<description><![CDATA[Herhangi bir dalga ÅŸekline sahip &#8220;f&#8221; frekanslÄ± periyodik bir sinyal, aÅŸaÄŸÄ±daki
bileÅŸenlerin toplamÄ±ndan oluÅŸur :






f frekanslÄ± sinÃ¼zoidal bileÅŸen; temel harmonik (h1)
frekanslarÄ±, temel harmonik frekansÄ±nÄ±n katlarÄ± olan sinuzoidal bileÅŸenler;
harmonikler (hn).
Ã–rnek
3. Harmonik oluÅŸumu
y(t) = h1(t) + h3(t)
 
]]></description>
			<content:encoded><![CDATA[<p>Herhangi bir dalga ÅŸekline sahip &#8220;f&#8221; frekanslÄ± periyodik bir sinyal, aÅŸaÄŸÄ±daki<br />
bileÅŸenlerin toplamÄ±ndan oluÅŸur :<span id="more-92"></span><br /><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p>
<p>f frekanslÄ± sinÃ¼zoidal bileÅŸen; <strong>temel harmonik</strong> (h1)<br />
frekanslarÄ±, temel harmonik frekansÄ±nÄ±n katlarÄ± olan sinuzoidal bileÅŸenler;</p>
<p><strong>harmonikler</strong> (hn).<br />
<strong>Ã–rnek</strong><br />
3. Harmonik oluÅŸumu<br />
y(t) = h1(t) + h3(t)</p>
<p align="center"><a href="../../rsm/harmonik-23.jpg" target="_blank"> <img src="../../rsm/harmonik-23.jpg" border="0" alt="" width="465" height="142" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/harmonik/harmonik-dalga-oluslumu-92.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Harmonik YÃ¼k Ã§eÅŸitleri</title>
		<link>http://www.indiriniz.com/harmonik/harmonik-yuk-cesitleri-89.html</link>
		<comments>http://www.indiriniz.com/harmonik/harmonik-yuk-cesitleri-89.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 16:18:02 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Harmonik]]></category>
		<category><![CDATA[kondansatÃ¶r]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/wp/?p=89</guid>
		<description><![CDATA[Elektrik sistemlerindeki yÃ¼kleri, doÄŸrusal ve doÄŸrusal olmayan yÃ¼kler olarak 2 farklÄ± grupta
toplayabiliriz. ÅŸebekedeki harmonik kirlilik, sistemdeki doÄŸrusal olmayan yÃ¼klerden










Harmonik YÃ¼k Ã§eÅŸitleri





Harmonik YÃ¼k Ã§eÅŸitleri
Elektrik sistemlerindeki yÃ¼kleri, doÄŸrusal ve doÄŸrusal olmayan yÃ¼kler        olarak 2 farklÄ± grupta
toplayabiliriz. ÅŸebekedeki harmonik kirlilik, sistemdeki doÄŸrusal olmayan        yÃ¼klerden
kaynaklanÄ±r. [...]]]></description>
			<content:encoded><![CDATA[<p>Elektrik sistemlerindeki yÃ¼kleri, doÄŸrusal ve doÄŸrusal olmayan yÃ¼kler olarak 2 farklÄ± grupta<br />
toplayabiliriz. ÅŸebekedeki harmonik kirlilik, sistemdeki doÄŸrusal olmayan yÃ¼klerden<span id="more-89"></span><br /><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p>
<table id="AutoNumber1" style="border-collapse: collapse; height: 444px;" border="0" cellspacing="0" cellpadding="0" width="540" bordercolor="#111111">
<tbody>
<tr>
<td colspan="3" width="540" height="13">
<p align="center"><em><strong>Harmonik YÃ¼k Ã§eÅŸitleri</strong></em></p>
</td>
</tr>
<tr>
<td width="115" height="105"><img src="../../rsm/harmonik-24.jpg" border="0" alt="" width="265" height="431" /></td>
<td width="4" height="105"></td>
<td width="421" height="105">Harmonik YÃ¼k Ã§eÅŸitleri</p>
<p>Elektrik sistemlerindeki yÃ¼kleri, doÄŸrusal ve doÄŸrusal olmayan yÃ¼kler        olarak 2 farklÄ± grupta<br />
toplayabiliriz. ÅŸebekedeki harmonik kirlilik, sistemdeki doÄŸrusal olmayan        yÃ¼klerden<br />
kaynaklanÄ±r. DoÄŸrusal olan ve olmayan yÃ¼kleri akÄ±m ve gerilime baÄŸlÄ±        olarak tanÄ±mlamak<br />
gerekirse;<br />
doÄŸrusal yÃ¼kler, akÄ±m dalga ÅŸekli, besleme gerilimi dalga ÅŸekli ile aynÄ±        formda olan<br />
yÃ¼klerdir: direnÃ§ler, endÃ¼ktanslar ve kondansatÃ¶rler. Harmonik Ã¼retmezler.<br />
(Bkz. ÅŸekil -1)</p>
<p>doÄŸrusal olmayan yÃ¼kler, akÄ±m dalga ÅŸekli, besleme gerilimi dalga        ÅŸeklinden farklÄ± olan<br />
yÃ¼klerdir; elektronik hÄ±z kontrol cihazlarÄ±, ark fÄ±rÄ±nlarÄ±, tristÃ¶r        kontrollÃ¼ doÄŸrultucular<br />
(redresÃ¶rler), kaynak makinalarÄ±, statik konvertÃ¶rler (UPS), floresan        lambalar vb&#8230; cihazlar.<br />
(Bkz. ÅŸekil &#8211; 2)</td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/harmonik/harmonik-yuk-cesitleri-89.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Harmonik SÄ±ralama</title>
		<link>http://www.indiriniz.com/harmonik/harmonik-siralama-87.html</link>
		<comments>http://www.indiriniz.com/harmonik/harmonik-siralama-87.html#comments</comments>
		<pubDate>Sat, 28 Mar 2009 16:16:20 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Harmonik]]></category>
		<category><![CDATA[endÃ¼ksiyon]]></category>
		<category><![CDATA[kondansatÃ¶r]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/wp/?p=87</guid>
		<description><![CDATA[Simetrik 3 fazlÄ± gÃ¼Ã§ sistemleri genellikle tek sÄ±ralÄ± harmoniklerden oluÅŸur;
3, 5, 7, 9,&#8230;n. Bu sayÄ±lar harmoniklerin sÄ±ralamasÄ±nÄ± belirler. Harmonik sÄ±ralama (n), bir






harmonik dalganÄ±n frekansÄ±nÄ± belirleyen Ã§arpandÄ±r. Harmonik bileÅŸenlerin frekanslarÄ±,
temel harmonik frekansÄ±nÄ±n katlarÄ± ÅŸeklindedir.
Ã–rnek: Temel harmonik frekansÄ± 50 Hz olduÄŸunda, harmonik sÄ±ralamasÄ± n:5 olan dalganÄ±n
frekansÄ± :
5 x 50 = 250 Hz.â€™dir.
Harmonik sÄ±rasÄ± yÃ¼kseldikÃ§e genlik deÄŸeri dÃ¼ÅŸer.
]]></description>
			<content:encoded><![CDATA[<p>Simetrik 3 fazlÄ± gÃ¼Ã§ sistemleri genellikle tek sÄ±ralÄ± harmoniklerden oluÅŸur;<br />
3, 5, 7, 9,&#8230;n. Bu sayÄ±lar harmoniklerin sÄ±ralamasÄ±nÄ± belirler. Harmonik sÄ±ralama (n), bir<span id="more-87"></span><br /><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><br />
harmonik dalganÄ±n frekansÄ±nÄ± belirleyen Ã§arpandÄ±r. Harmonik bileÅŸenlerin frekanslarÄ±,<br />
temel harmonik frekansÄ±nÄ±n katlarÄ± ÅŸeklindedir.<br />
Ã–rnek: Temel harmonik frekansÄ± 50 Hz olduÄŸunda, harmonik sÄ±ralamasÄ± n:5 olan dalganÄ±n<br />
frekansÄ± :<br />
5 x 50 = 250 Hz.â€™dir.<br />
Harmonik sÄ±rasÄ± yÃ¼kseldikÃ§e genlik deÄŸeri dÃ¼ÅŸer.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/harmonik/harmonik-siralama-87.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>