<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>indiriniz.com &#187; gerilim</title>
	<atom:link href="http://www.indiriniz.com/kompanzasyon/gerilim/feed" rel="self" type="application/rss+xml" />
	<link>http://www.indiriniz.com</link>
	<description>Kompanzasyon Enerji kalitesi GÃ¼nlÃ¼ÄŸÃ¼</description>
	<lastBuildDate>Thu, 14 May 2009 13:51:35 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.8.4</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>Gerilim YanÄ±lgÄ±sÄ± ve Faz KaymasÄ± SÄ±nÄ±rlarÄ±</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/gerilim-yanilgisi-ve-faz-kaymasi-sinirlari-353.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/gerilim-yanilgisi-ve-faz-kaymasi-sinirlari-353.html#comments</comments>
		<pubDate>Thu, 14 May 2009 13:45:54 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[AkÄ±m Gerilim TrafolarÄ±]]></category>
		<category><![CDATA[Faz]]></category>
		<category><![CDATA[gerilim]]></category>
		<category><![CDATA[KaymasÄ±]]></category>
		<category><![CDATA[SÄ±nÄ±rlarÄ±]]></category>
		<category><![CDATA[ve]]></category>
		<category><![CDATA[YanÄ±lgÄ±sÄ±]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=353</guid>
		<description><![CDATA[Koruma gerilim transformatÃ¶rlerinin, anma frekansÄ±nda gerilim yanÄ±lgÄ±sÄ± ve faz kaymasÄ±,
yÃ¼k, anma yÃ¼kÃ¼nÃ¼n %25 &#8211; %100â€™ Ã¼ arasÄ±nda ve gerilim de, primer anma geriliminin
anma gerilim yÃ¼kseltme katsayÄ±sÄ± ile (1.2 â€“ 1.5 veya 1.9) Ã§arpÄ±mÄ±ndan elde edilen gerilim
deÄŸerinde iken ve gÃ¼Ã§ katsayÄ±sÄ± = 0.8 (endÃ¼ktif) durumu iÃ§in Tablo 25â€™ de gÃ¶sterilen
deÄŸerleri aÅŸmamalÄ±dÄ±r.






Not:
Ä°ki ayrÄ± sekonder sargÄ±sÄ± olan bir [...]]]></description>
			<content:encoded><![CDATA[<p>Koruma gerilim transformatÃ¶rlerinin, anma frekansÄ±nda gerilim yanÄ±lgÄ±sÄ± ve faz kaymasÄ±,<br />
yÃ¼k, anma yÃ¼kÃ¼nÃ¼n %25 &#8211; %100â€™ Ã¼ arasÄ±nda ve gerilim de, primer anma geriliminin<br />
anma gerilim yÃ¼kseltme katsayÄ±sÄ± ile (1.2 â€“ 1.5 veya 1.9) Ã§arpÄ±mÄ±ndan elde edilen gerilim<br />
deÄŸerinde iken ve gÃ¼Ã§ katsayÄ±sÄ± = 0.8 (endÃ¼ktif) durumu iÃ§in Tablo 25â€™ de gÃ¶sterilen<br />
deÄŸerleri aÅŸmamalÄ±dÄ±r.<span id="more-353"></span><br /><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p>
<p><strong>Not:</strong><br />
Ä°ki ayrÄ± sekonder sargÄ±sÄ± olan bir koruma gerilim transformatÃ¶rÃ¼nde, sargÄ±larÄ±n birbirine<br />
etkileri nedeniyle, herbir sekonder sargÄ±sÄ± iÃ§in iki anma Ã§Ä±kÄ±ÅŸ gÃ¼cÃ¼ bandÄ± belirtilmelidir.<br />
Bu bandlarÄ±n herbirinin Ã¼st sÄ±nÄ±rÄ± anma Ã§Ä±kÄ±ÅŸ gÃ¼Ã§leri iÃ§in verilen standard deÄŸere eÅŸit<br />
olmalÄ±dÄ±r. Bir sargÄ±, belirlenen anma Ã§Ä±kÄ±ÅŸ gÃ¼cÃ¼ bandÄ±nÄ±n Ã¼st sÄ±nÄ±r deÄŸerinin %0 &#8211; %100â€™ Ã¼<br />
arasÄ±nda yÃ¼klÃ¼ iken, diÄŸer sargÄ± kendisiyle ilgili doÄŸruluk sÄ±nÄ±fÄ± koÅŸulunu saÄŸlamalÄ±dÄ±r.<br />
Bu koÅŸula uygunluÄŸun yalnÄ±z sÄ±nÄ±r deÄŸerler iÃ§in denenmesi yeterlidir. Anma Ã§Ä±kÄ±ÅŸ gÃ¼Ã§leri<br />
bandÄ± belirtilmediÄŸinde, bu bandlar, her sargÄ±nÄ±n anma Ã§Ä±kÄ±ÅŸ gÃ¼cÃ¼nÃ¼n %25 &#8211; %100â€™ Ã¼<br />
arasÄ±nda alÄ±nÄ±r.</p>
<div id="attachment_354" class="wp-caption alignnone" style="width: 582px"><img class="size-full wp-image-354" title="Koruma Gerilim TransformatÃ¶rÃ¼ Standard DoÄŸruluk SÄ±nÄ±flarÄ±" src="http://www.indiriniz.com/wp-content/uploads/2009/05/adsiz-2.jpg" alt="Koruma Gerilim TransformatÃ¶rÃ¼ Standard DoÄŸruluk SÄ±nÄ±flarÄ±" width="572" height="128" /><p class="wp-caption-text">Koruma Gerilim TransformatÃ¶rÃ¼ Standard DoÄŸruluk SÄ±nÄ±flarÄ±</p></div>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/gerilim-yanilgisi-ve-faz-kaymasi-sinirlari-353.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Koruma Gerilim TransformatÃ¶rlerinde Standard DoÄŸruluk SÄ±nÄ±flarÄ±</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/koruma-gerilim-transformatorlerinde-standard-dogruluk-siniflari-351.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/koruma-gerilim-transformatorlerinde-standard-dogruluk-siniflari-351.html#comments</comments>
		<pubDate>Thu, 14 May 2009 13:42:42 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[AkÄ±m Gerilim TrafolarÄ±]]></category>
		<category><![CDATA[DoÄŸruluk]]></category>
		<category><![CDATA[gerilim]]></category>
		<category><![CDATA[Koruma]]></category>
		<category><![CDATA[SÄ±nÄ±flarÄ±]]></category>
		<category><![CDATA[Standard]]></category>
		<category><![CDATA[TransformatÃ¶rlerinde]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=351</guid>
		<description><![CDATA[Standard doÄŸruluk sÄ±nÄ±fÄ±, koruma gerilim transformatÃ¶rlerinde,
3P â€“ 6P olarak tanÄ±mlanmÄ±ÅŸtÄ±r.
Gerilim transformatÃ¶rÃ¼nÃ¼n %5 anma gerilimi ile gerilim yÃ¼kseltme katsayÄ±sÄ±
ile Ã§arpÄ±lmÄ±ÅŸ anma gerilimindeki % gerilim yanÄ±lgÄ±sÄ±nÄ±n P harfi Ã¶nÃ¼ndeki
rakamÄ± aÅŸmamasÄ± istenir.
Keza faz kaymasÄ±, buna ait tablodaki deÄŸerleri aÅŸmamalÄ±dÄ±r.
%2 Anma geriliminde hata limiti, %5 anma gerilimi iÃ§in verilen hata limitinin
2 mislinden bÃ¼yÃ¼k olmamalÄ±dÄ±r.
Ä°malatÃ§Ä± ile mÃ¼ÅŸteri arasÄ±nda yapÄ±lacak anlaÅŸma [...]]]></description>
			<content:encoded><![CDATA[<p>Standard doÄŸruluk sÄ±nÄ±fÄ±, koruma gerilim transformatÃ¶rlerinde,<br />
3P â€“ 6P olarak tanÄ±mlanmÄ±ÅŸtÄ±r.<br />
Gerilim transformatÃ¶rÃ¼nÃ¼n %5 anma gerilimi ile gerilim yÃ¼kseltme katsayÄ±sÄ±<br />
ile Ã§arpÄ±lmÄ±ÅŸ anma gerilimindeki % gerilim yanÄ±lgÄ±sÄ±nÄ±n P harfi Ã¶nÃ¼ndeki<br />
rakamÄ± aÅŸmamasÄ± istenir.<br />
Keza faz kaymasÄ±, buna ait tablodaki deÄŸerleri aÅŸmamalÄ±dÄ±r.<br />
%2 Anma geriliminde hata limiti, %5 anma gerilimi iÃ§in verilen hata limitinin<br />
2 mislinden bÃ¼yÃ¼k olmamalÄ±dÄ±r.<br />
Ä°malatÃ§Ä± ile mÃ¼ÅŸteri arasÄ±nda yapÄ±lacak anlaÅŸma neticesi, %5 gerilim limitinde<br />
gerilim hatasÄ±<br />
(%5 x gerilim faktÃ¶rÃ¼) tablodaki deÄŸerlerden farklÄ± deÄŸerlerde olabilir.<br />
(Standard anma limit faktÃ¶rleri 1.2 â€“ 1.5 â€“ 1.9)<span id="more-351"></span><br /><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p>
<p><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 728x15, oluÅŸturulma 20.11.2008 */
google_ad_slot = "6035974834";
google_ad_width = 728;
google_ad_height = 15;
//-->
</script>
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p> ]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/koruma-gerilim-transformatorlerinde-standard-dogruluk-siniflari-351.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Ã–lÃ§Ã¼ Gerilim TransformatÃ¶rleri Etiketinin MarkalamasÄ±</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-gerilim-transformatorleri-etiketinin-markalamasi-345.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-gerilim-transformatorleri-etiketinin-markalamasi-345.html#comments</comments>
		<pubDate>Thu, 14 May 2009 13:35:57 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[AkÄ±m Gerilim TrafolarÄ±]]></category>
		<category><![CDATA[Etiketinin]]></category>
		<category><![CDATA[gerilim]]></category>
		<category><![CDATA[MarkalamasÄ±]]></category>
		<category><![CDATA[Ã¶lÃ§Ã¼]]></category>
		<category><![CDATA[TransformatÃ¶rleri]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=345</guid>
		<description><![CDATA[Anma PlakasÄ±nÄ±n MarkalanmasÄ±nda belirtilen bilgileri ihtiva eder. DoÄŸruluk sÄ±nÄ±fÄ±, ilgili anma
Ã§Ä±kÄ±ÅŸ gÃ¼cÃ¼ ile birlikte verilmelidir. (Ã–rnek: 100VA â€“ SÄ±nÄ±f:0.5)
Not:






Anma etiketi, bu transformatÃ¶rÃ¼n realize edilebileceÄŸi muhtelif Ã§Ä±kÄ±ÅŸ gÃ¼cÃ¼
ve bununla ilgili doÄŸruluk sÄ±nÄ±fÄ± bilgileri ile de donatÄ±labilir.
]]></description>
			<content:encoded><![CDATA[<p><a class="title" rel="bookmark" href="../akim-gerilim-trafolari/anma-plakasinin-markalanmasi-328.html">Anma PlakasÄ±nÄ±n MarkalanmasÄ±</a>nda belirtilen bilgileri ihtiva eder. DoÄŸruluk sÄ±nÄ±fÄ±, ilgili anma<br />
Ã§Ä±kÄ±ÅŸ gÃ¼cÃ¼ ile birlikte verilmelidir. (Ã–rnek: 100VA â€“ SÄ±nÄ±f:0.5)<br />
<strong>Not:</strong><span id="more-345"></span><br /><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p>
<p>Anma etiketi, bu transformatÃ¶rÃ¼n realize edilebileceÄŸi muhtelif Ã§Ä±kÄ±ÅŸ gÃ¼cÃ¼<br />
ve bununla ilgili doÄŸruluk sÄ±nÄ±fÄ± bilgileri ile de donatÄ±labilir.</p>
<p><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 728x15, oluÅŸturulma 20.11.2008 */
google_ad_slot = "6035974834";
google_ad_width = 728;
google_ad_height = 15;
//-->
</script>
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p> ]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-gerilim-transformatorleri-etiketinin-markalamasi-345.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Ã–lÃ§Ã¼ Gerilim TransformatÃ¶rlerinin DoÄŸruluÄŸu Ä°Ã§in Rutin Testler</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-gerilim-transformatorlerinin-dogrulugu-icin-rutin-testler-343.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-gerilim-transformatorlerinin-dogrulugu-icin-rutin-testler-343.html#comments</comments>
		<pubDate>Thu, 14 May 2009 13:33:26 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[AkÄ±m Gerilim TrafolarÄ±]]></category>
		<category><![CDATA[DoÄŸruluÄŸu]]></category>
		<category><![CDATA[gerilim]]></category>
		<category><![CDATA[Ä°Ã§in]]></category>
		<category><![CDATA[Ã¶lÃ§Ã¼]]></category>
		<category><![CDATA[Rutin]]></category>
		<category><![CDATA[Testler]]></category>
		<category><![CDATA[TransformatÃ¶rlerinin]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=343</guid>
		<description><![CDATA[Bu transformatÃ¶rlerin doÄŸruluk testleri yukarÄ±daki paragraf ile aynÄ±dÄ±r. Fakat,
bu rutin testler, daha pratik hale sokularak daha az sayÄ±da gerilim ve yÃ¼kte
yapÄ±lmasÄ±na mÃ¼saade edilir. Bu testler ile Ã¶zellikle, yukarÄ±daki paragrafta
belirlenen limitlerin tutulacaÄŸÄ±nÄ±n ve uygunluÄŸunun kanÄ±tlanmasÄ± gerekir.






Kaynak Alce
]]></description>
			<content:encoded><![CDATA[<p>Bu transformatÃ¶rlerin doÄŸruluk testleri yukarÄ±daki paragraf ile aynÄ±dÄ±r. Fakat,<br />
bu rutin testler, daha pratik hale sokularak daha az sayÄ±da gerilim ve yÃ¼kte<br />
yapÄ±lmasÄ±na mÃ¼saade edilir. Bu testler ile Ã¶zellikle, yukarÄ±daki paragrafta<br />
belirlenen limitlerin tutulacaÄŸÄ±nÄ±n ve uygunluÄŸunun kanÄ±tlanmasÄ± gerekir.<span id="more-343"></span><br /><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><br />
Kaynak Alce</p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-gerilim-transformatorlerinin-dogrulugu-icin-rutin-testler-343.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Ã–lÃ§Ã¼ Gerilim TransformatÃ¶rlerinin DoÄŸruluÄŸu Ä°Ã§in Gerekli Tip Testleri</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-gerilim-transformatorlerinin-dogrulugu-icin-gerekli-tip-testleri-341.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-gerilim-transformatorlerinin-dogrulugu-icin-gerekli-tip-testleri-341.html#comments</comments>
		<pubDate>Thu, 14 May 2009 13:31:50 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[AkÄ±m Gerilim TrafolarÄ±]]></category>
		<category><![CDATA[DoÄŸruluÄŸu]]></category>
		<category><![CDATA[Gerekli]]></category>
		<category><![CDATA[gerilim]]></category>
		<category><![CDATA[Ã¶lÃ§Ã¼]]></category>
		<category><![CDATA[Testleri]]></category>
		<category><![CDATA[Tip]]></category>
		<category><![CDATA[TransformatÃ¶rlerinin]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=341</guid>
		<description><![CDATA[Ã–lÃ§Ã¼ Gerilim TransformatÃ¶rlerinde Gerilim YanÄ±lgÄ±sÄ± ve Faz KaymasÄ± SÄ±nÄ±rlarÄ± na  gÃ¶re, gerilim yanÄ±lgÄ±sÄ± ve faz kaymasÄ± sÄ±nÄ±rlarÄ±nÄ±n kontrolunun
ardÄ±ndan anma geriliminin %80 &#8211; %100 ve %120â€™ sinde, anma frekansÄ±nda ve
anma yÃ¼kÃ¼nÃ¼n %25 ile %100â€™ de ayrÄ± ayrÄ± teste tabi tutulurlar.






Kaynak Alce
]]></description>
			<content:encoded><![CDATA[<p><a class="title" rel="bookmark" href="../akim-gerilim-trafolari/olcu-gerilim-transformatorlerinde-gerilim-yanilgisi-ve-faz-kaymasi-sinirlari-334.html">Ã–lÃ§Ã¼ Gerilim TransformatÃ¶rlerinde Gerilim YanÄ±lgÄ±sÄ± ve Faz KaymasÄ± SÄ±nÄ±rlarÄ± na </a> gÃ¶re, gerilim yanÄ±lgÄ±sÄ± ve faz kaymasÄ± sÄ±nÄ±rlarÄ±nÄ±n kontrolunun<br />
ardÄ±ndan anma geriliminin %80 &#8211; %100 ve %120â€™ sinde, anma frekansÄ±nda ve<br />
anma yÃ¼kÃ¼nÃ¼n %25 ile %100â€™ de ayrÄ± ayrÄ± teste tabi tutulurlar.<span id="more-341"></span><br /><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p>
<p>Kaynak Alce</p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-gerilim-transformatorlerinin-dogrulugu-icin-gerekli-tip-testleri-341.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Ã–lÃ§Ã¼ Gerilim TransformatÃ¶rlerinde Gerilim YanÄ±lgÄ±sÄ± ve Faz KaymasÄ± SÄ±nÄ±rlarÄ±</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-gerilim-transformatorlerinde-gerilim-yanilgisi-ve-faz-kaymasi-sinirlari-334.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-gerilim-transformatorlerinde-gerilim-yanilgisi-ve-faz-kaymasi-sinirlari-334.html#comments</comments>
		<pubDate>Mon, 20 Apr 2009 22:16:56 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[AkÄ±m Gerilim TrafolarÄ±]]></category>
		<category><![CDATA[Faz]]></category>
		<category><![CDATA[gerilim]]></category>
		<category><![CDATA[KaymasÄ±]]></category>
		<category><![CDATA[Ã¶lÃ§Ã¼]]></category>
		<category><![CDATA[SÄ±nÄ±rlarÄ±]]></category>
		<category><![CDATA[TransformatÃ¶rlerinde]]></category>
		<category><![CDATA[ve]]></category>
		<category><![CDATA[YanÄ±lgÄ±sÄ±]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=334</guid>
		<description><![CDATA[Ã–lÃ§Ã¼ Gerilim TransformatÃ¶rlerinde Gerilim YanÄ±lgÄ±sÄ± ve Faz KaymasÄ± SÄ±nÄ±rlarÄ±
IEC 60044-2/1997-02 â€“ Clause 12.2
Ã–lÃ§Ã¼ gerilim transformatÃ¶rlerinin anma frekansÄ±nda gerilim yanÄ±lgÄ±sÄ± ve
faz kaymasÄ±, yÃ¼k anma yÃ¼kÃ¼nÃ¼n %25 &#8211; %100â€™ Ã¼ arasÄ±nda iken, primer
anma geriliminin %80 &#8211; %120â€™ si arasÄ±nda bulunan bÃ¼tÃ¼n gerilimlerde
ve gÃ¼Ã§ katsayÄ±sÄ± =0.8 (endÃ¼ktif) durumu iÃ§in Tablo 24â€™ de verilen
deÄŸerleri aÅŸmamalÄ±dÄ±r.






TransformatÃ¶rÃ¼n bir parÃ§asÄ± olarak sigorta [...]]]></description>
			<content:encoded><![CDATA[<p>Ã–lÃ§Ã¼ Gerilim TransformatÃ¶rlerinde Gerilim YanÄ±lgÄ±sÄ± ve Faz KaymasÄ± SÄ±nÄ±rlarÄ±<br />
IEC 60044-2/1997-02 â€“ Clause 12.2<br />
Ã–lÃ§Ã¼ gerilim transformatÃ¶rlerinin anma frekansÄ±nda gerilim yanÄ±lgÄ±sÄ± ve<br />
faz kaymasÄ±, yÃ¼k anma yÃ¼kÃ¼nÃ¼n %25 &#8211; %100â€™ Ã¼ arasÄ±nda iken, primer<br />
anma geriliminin %80 &#8211; %120â€™ si arasÄ±nda bulunan bÃ¼tÃ¼n gerilimlerde<br />
ve gÃ¼Ã§ katsayÄ±sÄ± =0.8 (endÃ¼ktif) durumu iÃ§in Tablo 24â€™ de verilen<br />
deÄŸerleri aÅŸmamalÄ±dÄ±r.<span id="more-334"></span><br /><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p>
<p>TransformatÃ¶rÃ¼n bir parÃ§asÄ± olarak sigorta veya direnÃ§ler de bulunduÄŸunda,<br />
bunlarÄ±n etkisini de kapsamak amacÄ±yla, yanÄ±lgÄ±lar bunlar dahil edilerek,<br />
gerilim transformatÃ¶rÃ¼nÃ¼n uÃ§larÄ±nda belirlenmelidir.</p>
<p><div id="attachment_335" class="wp-caption alignnone" style="width: 570px"><img src="http://www.indiriniz.com/wp-content/uploads/2009/04/tablo-24.jpg" alt="Tablo 24.. Ã–lÃ§Ã¼ gerilim transformatÃ¶rleri gerilim yanÄ±lgÄ±sÄ± ve faz kaymasÄ± standard sÄ±nÄ±r deÄŸerleri" title="tablo-24" width="560" height="170" class="size-full wp-image-335" /><p class="wp-caption-text">Tablo 24.. Ã–lÃ§Ã¼ gerilim transformatÃ¶rleri gerilim yanÄ±lgÄ±sÄ± ve faz kaymasÄ± standard sÄ±nÄ±r deÄŸerleri</p></div><br />
Not:<br />
Ä°ki ayrÄ± sekonder sargÄ±sÄ± olan bir Ã¶lÃ§Ã¼ gerilim transformatÃ¶rÃ¼nde, sargÄ±larÄ±n<br />
birbirine etkileri nedeniyle, herbir sekonder sargÄ± iÃ§in iki anma Ã§Ä±kÄ±ÅŸ gÃ¼cÃ¼<br />
bandÄ± belirtilmelidir.<br />
Bu bandlarÄ±n herbirinin Ã¼st sÄ±nÄ±rÄ± anma Ã§Ä±kÄ±ÅŸ gÃ¼Ã§leri iÃ§in verilen standard<br />
deÄŸere eÅŸit olmalÄ±dÄ±r. Bir sargÄ±, belirlenen anma Ã§Ä±kÄ±ÅŸ gÃ¼cÃ¼ bandÄ±nÄ±n Ã¼st<br />
sÄ±nÄ±r deÄŸerinin %0(sÄ±fÄ±r) &#8211; %100â€™ Ã¼ arasÄ±nda yÃ¼klÃ¼ iken, diÄŸer sargÄ±<br />
kendisiyle ilgili doÄŸruluk sÄ±nÄ±fÄ± koÅŸulunu saÄŸlamalÄ±dÄ±r.<br />
Bu koÅŸula uygunluÄŸun yalnÄ±z kur deÄŸerler iÃ§in denenmesi yeterlidir.<br />
Anma Ã§Ä±kÄ±ÅŸ gÃ¼Ã§leri bandÄ± belirtilmediÄŸinde, bu bandlar, her sargÄ±nÄ±n anma<br />
Ã§Ä±kÄ±ÅŸ gÃ¼cÃ¼nÃ¼n %25 &#8211; %100â€™ Ã¼ arasÄ±nda olmalÄ±dÄ±r.<br />
SargÄ±lardan birisi seyrek olarak veya kÄ±sa sÃ¼reli yÃ¼klendiÄŸinde, bu sargÄ±nÄ±n<br />
diÄŸer sargÄ±ya etkisi gÃ¶zÃ¶nÃ¼ne alÄ±nmayabilir.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-gerilim-transformatorlerinde-gerilim-yanilgisi-ve-faz-kaymasi-sinirlari-334.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Anma PlakasÄ±nÄ±n MarkalanmasÄ±</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/anma-plakasinin-markalanmasi-328.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/anma-plakasinin-markalanmasi-328.html#comments</comments>
		<pubDate>Mon, 20 Apr 2009 22:10:02 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[AkÄ±m Gerilim TrafolarÄ±]]></category>
		<category><![CDATA[anma]]></category>
		<category><![CDATA[Anma PlakasÄ±nÄ±n MarkalanmasÄ±]]></category>
		<category><![CDATA[gerilim]]></category>
		<category><![CDATA[plakalarÄ±]]></category>
		<category><![CDATA[TransformatÃ¶rleri]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=328</guid>
		<description><![CDATA[Anma PlakasÄ±nÄ±n MarkalanmasÄ±
BÃ¼tÃ¼n gerilim transformatÃ¶rleri anma plakalarÄ±, en azÄ±ndan aÅŸaÄŸÄ±daki bilgileri iÃ§ermelidir.
- Kendisini rahatlÄ±kla tespit imkanÄ± verecek, imalatÃ§Ä± adÄ± veya markasÄ±,
- Seri numarasÄ± veya dizayn tipi, mÃ¼mkÃ¼nse her ikisi,
- Primer ve sekonder anma gerilimleri (Ã–rnek 33000/100V â€“ 33/0.1kV)
- Anma frekansÄ±






- Anma Ã§Ä±kÄ±ÅŸ gÃ¼cÃ¼ ve bununla ilgili hassasiyet sÄ±nÄ±fÄ± (Ã–rnek: 60VA Klas 1)
Not:
Ä°ki sekonder sargÄ±lÄ± olmasÄ± [...]]]></description>
			<content:encoded><![CDATA[<p>Anma PlakasÄ±nÄ±n MarkalanmasÄ±<br />
BÃ¼tÃ¼n gerilim transformatÃ¶rleri anma plakalarÄ±, en azÄ±ndan aÅŸaÄŸÄ±daki bilgileri iÃ§ermelidir.<br />
- Kendisini rahatlÄ±kla tespit imkanÄ± verecek, imalatÃ§Ä± adÄ± veya markasÄ±,<br />
- Seri numarasÄ± veya dizayn tipi, mÃ¼mkÃ¼nse her ikisi,<br />
- Primer ve sekonder anma gerilimleri (Ã–rnek 33000/100V â€“ 33/0.1kV)<br />
- Anma frekansÄ±<span id="more-328"></span><br /><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p>
<p>- Anma Ã§Ä±kÄ±ÅŸ gÃ¼cÃ¼ ve bununla ilgili hassasiyet sÄ±nÄ±fÄ± (Ã–rnek: 60VA Klas 1)<br />
Not:<br />
Ä°ki sekonder sargÄ±lÄ± olmasÄ± durumunda, markalamada her iki sargÄ±nÄ±n VA olarak sekonder<br />
gÃ¼cÃ¼ne iliÅŸik hassasiyet sÄ±nÄ±fÄ±, anma gerilimleri anma plakasÄ±nda bulunmalÄ±dÄ±r.<br />
- Sistemin maksimum iÅŸletme gerilimi (Ã–rnek: Um=36kV )<br />
- Ä°zolasyon test anma gerilimleri (Ã–rnek: 70 / 170kV)<br />
Not:<br />
YukarÄ±daki son iki ÅŸÄ±k markalamada birlikte kullanÄ±labilirler (Ã–rnek: 36 / 70 / 170kV)<br />
BÃ¼tÃ¼n bu bilgiler silinmeyecek ÅŸekilde, gerilim transformatÃ¶rÃ¼ Ã¼zerinde veya emniyetli<br />
ÅŸekilde transformatÃ¶rÃ¼n Ã¼zerine konulmuÅŸ anma etiketi Ã¼zerinde bulunmalÄ±dÄ±r.<br />
AyrÄ±ca, etikette yer olduÄŸu mÃ¼ddetÃ§e aÅŸaÄŸÄ±daki bilgilerinde anma etiketi Ã¼zerinde<br />
bulunmasÄ± yararlÄ± olacaktÄ±r.<br />
- Anma gerilim faktÃ¶rÃ¼ ve bununla ilgili anma zamanÄ± (Ã–rnek 1.9Un 8h)<br />
- Ä°zole malzeme sÄ±nÄ±fÄ±nÄ±n A dÄ±ÅŸÄ±nda olmasÄ± halinde, bunun belirtilmesi. (Ã–rnek: E)<br />
Not:<br />
Ä°malatta, birkaÃ§ sÄ±nÄ±flÄ± izolasyon malzemesi kullanÄ±lmasÄ± halinde, sargÄ± bobinlerinin<br />
sÄ±nÄ±fÄ±nda rol oynayacak izole malzeme sÄ±nÄ±fÄ± belirtilmelidir.<br />
- Birden fazla sekonder sargÄ± olmasÄ± durumunda, bunlarÄ±n her birinin kullanÄ±lma<br />
amacÄ± belirtilmeli ve onunla ilgili uygun terminal markalamasÄ± yapÄ±lmalÄ±dÄ±r.<br />
IEC 60044-2/1997-02 â€“ Clause 11.1</p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/anma-plakasinin-markalanmasi-328.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Ã–lÃ§Ã¼ Gerilim TransformatÃ¶rleri TasarÄ±mÄ±nda DoÄŸruluk SÄ±nÄ±flarÄ±</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-gerilim-transformatorleri-tasariminda-dogruluk-siniflari-330.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-gerilim-transformatorleri-tasariminda-dogruluk-siniflari-330.html#comments</comments>
		<pubDate>Mon, 20 Apr 2009 10:11:37 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[AkÄ±m Gerilim TrafolarÄ±]]></category>
		<category><![CDATA[DoÄŸruluk]]></category>
		<category><![CDATA[gerilim]]></category>
		<category><![CDATA[Ã¶lÃ§Ã¼]]></category>
		<category><![CDATA[Ã–lÃ§Ã¼ Gerilim TransformatÃ¶rleri TasarÄ±mÄ±nda DoÄŸruluk SÄ±nÄ±flarÄ±]]></category>
		<category><![CDATA[SÄ±nÄ±flarÄ±]]></category>
		<category><![CDATA[TasarÄ±mÄ±nda]]></category>
		<category><![CDATA[TransformatÃ¶rleri]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=330</guid>
		<description><![CDATA[Ã–lÃ§Ã¼ Gerilim TransformatÃ¶rleri TasarÄ±mÄ±nda DoÄŸruluk SÄ±nÄ±flarÄ±
Ã–lÃ§Ã¼ transformatÃ¶rleri iÃ§in doÄŸruluk sÄ±nÄ±fÄ± tasarÄ±mÄ±nda, izin verilen en yÃ¼ksek yÃ¼zde
gerilim hatasÄ±, anma gerilimi ve anma yÃ¼kÃ¼ ile yÃ¼klenmiÅŸ olarak hassasiyet sÄ±nÄ±fÄ±na
ait deÄŸer sÄ±nÄ±rlarÄ±nÄ± aÅŸmamasÄ± istenir.






]]></description>
			<content:encoded><![CDATA[<p>Ã–lÃ§Ã¼ Gerilim TransformatÃ¶rleri TasarÄ±mÄ±nda DoÄŸruluk SÄ±nÄ±flarÄ±<br />
Ã–lÃ§Ã¼ transformatÃ¶rleri iÃ§in doÄŸruluk sÄ±nÄ±fÄ± tasarÄ±mÄ±nda, izin verilen en yÃ¼ksek yÃ¼zde<br />
gerilim hatasÄ±, anma gerilimi ve anma yÃ¼kÃ¼ ile yÃ¼klenmiÅŸ olarak hassasiyet sÄ±nÄ±fÄ±na<br />
ait deÄŸer sÄ±nÄ±rlarÄ±nÄ± aÅŸmamasÄ± istenir.<span id="more-330"></span><br /><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-gerilim-transformatorleri-tasariminda-dogruluk-siniflari-330.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Ã–lÃ§Ã¼ Gerilim TransformatÃ¶rlerinde Standard DoÄŸruluk SÄ±nÄ±flarÄ±</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-gerilim-transformatorlerinde-standard-dogruluk-siniflari-332.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-gerilim-transformatorlerinde-standard-dogruluk-siniflari-332.html#comments</comments>
		<pubDate>Sun, 19 Apr 2009 22:13:27 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[AkÄ±m Gerilim TrafolarÄ±]]></category>
		<category><![CDATA[DoÄŸruluk]]></category>
		<category><![CDATA[gerilim]]></category>
		<category><![CDATA[Ã¶lÃ§Ã¼]]></category>
		<category><![CDATA[SÄ±nÄ±flarÄ±]]></category>
		<category><![CDATA[Standard]]></category>
		<category><![CDATA[TransformatÃ¶rlerinde]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=332</guid>
		<description><![CDATA[Ã–lÃ§Ã¼ Gerilim TransformatÃ¶rlerinde Standard DoÄŸruluk SÄ±nÄ±flarÄ±
IEC 60044-2/1997-02 â€“ Clause 12.1.1
Standard doÄŸruluk sÄ±nÄ±flarÄ± endÃ¼ktif gerilim transformatÃ¶rlerinde;






0.1 â€“ 0.2 â€“ 0.5 â€“ 1.0 â€“ 3.0
olarak tanÄ±mlanmÄ±ÅŸtÄ±r.
]]></description>
			<content:encoded><![CDATA[<p>Ã–lÃ§Ã¼ Gerilim TransformatÃ¶rlerinde Standard DoÄŸruluk SÄ±nÄ±flarÄ±<br />
IEC 60044-2/1997-02 â€“ Clause 12.1.1<br />
Standard doÄŸruluk sÄ±nÄ±flarÄ± endÃ¼ktif gerilim transformatÃ¶rlerinde;<span id="more-332"></span><br /><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 336x280, oluþturulma 20.07.2008 */
google_ad_slot = "5456503445";
google_ad_width = 336;
google_ad_height = 280;
//-->
</script><br />
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p>
<p><strong>0.1 â€“ 0.2 â€“ 0.5 â€“ 1.0 â€“ 3.0</strong></p>
<p>olarak tanÄ±mlanmÄ±ÅŸtÄ±r.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/olcu-gerilim-transformatorlerinde-standard-dogruluk-siniflari-332.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>KÄ±smi BoÅŸalmalarÄ±n Ã–lÃ§Ã¼lmesi</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/kismi-bosalmalarin-olculmesi-315.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/kismi-bosalmalarin-olculmesi-315.html#comments</comments>
		<pubDate>Sun, 19 Apr 2009 21:58:49 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[AkÄ±m Gerilim TrafolarÄ±]]></category>
		<category><![CDATA[gerilim]]></category>
		<category><![CDATA[topraklanmÄ±ÅŸ]]></category>
		<category><![CDATA[transformatÃ¶r]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=315</guid>
		<description><![CDATA[KÄ±smi BoÅŸalmalarÄ±n Ã–lÃ§Ã¼lmesi
Test devresi ve kullanÄ±lacak cihazlara iliÅŸkin bilgi IEC 270â€™ de detaylÄ± olarak verilmiÅŸtir.
TopraklanmÄ±ÅŸ gerilim transformatÃ¶rlerinde IEC 60044-2 Clause 9.2.4.2, topraklanmamÄ±ÅŸ
gerilim transformatÃ¶rlerinde ise, Clause 9.2.4.3â€™ de belirlenmiÅŸ yÃ¶ntemler ile gerÃ§ekleÅŸtirilir.
Test cihazÄ± 5pC boÅŸalma seviyesini Ã¶lÃ§ebilecek hassasiyette olmalÄ±dÄ±r.
Bu cihazda kullanÄ±lacak, geniÅŸ bandlÄ± filtre band geniÅŸliÄŸi min. 100kHz, ve band Ã¼st
geniÅŸliÄŸi 1.2MHzâ€™ i geÃ§meyecek ÅŸekilde olacaktÄ±r.
Filtre [...]]]></description>
			<content:encoded><![CDATA[<p><strong>KÄ±smi BoÅŸalmalarÄ±n Ã–lÃ§Ã¼lmesi</strong><br />
Test devresi ve kullanÄ±lacak cihazlara iliÅŸkin bilgi IEC 270â€™ de detaylÄ± olarak verilmiÅŸtir.<br />
TopraklanmÄ±ÅŸ gerilim transformatÃ¶rlerinde IEC 60044-2 Clause 9.2.4.2, topraklanmamÄ±ÅŸ<br />
gerilim transformatÃ¶rlerinde ise, Clause 9.2.4.3â€™ de belirlenmiÅŸ yÃ¶ntemler ile gerÃ§ekleÅŸtirilir.<br />
Test cihazÄ± 5pC boÅŸalma seviyesini Ã¶lÃ§ebilecek hassasiyette olmalÄ±dÄ±r.<br />
Bu cihazda kullanÄ±lacak, geniÅŸ bandlÄ± filtre band geniÅŸliÄŸi min. 100kHz, ve band Ã¼st<br />
geniÅŸliÄŸi 1.2MHzâ€™ i geÃ§meyecek ÅŸekilde olacaktÄ±r.<br />
Filtre dar band olacak ise, rezonans frekansÄ± 0.15MHz ile 2.0MHzâ€™ lik saha iÃ§erisinde<br />
olmak Ã¼zere, 0.50 â€“ 2.0MHzâ€™ lik sahada seÃ§ilir.<br />
Ã–lÃ§me, bu bandlardan en uygun sonuÃ§ veren ile gerÃ§ekleÅŸtirilecektir.</p>