<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>indiriniz.com &#187; Frekansında</title>
	<atom:link href="http://www.indiriniz.com/kompanzasyon/frekansinda/feed" rel="self" type="application/rss+xml" />
	<link>http://www.indiriniz.com</link>
	<description>Kompanzasyon Enerji kalitesi Günlüğü</description>
	<lastBuildDate>Thu, 14 May 2009 13:51:35 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.1</generator>
		<item>
		<title>Sekonder Sargının Şebeke Frekansında Gerilime Dayanma Deneyi</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/sekonder-sarginin-sebeke-frekansinda-gerilime-dayanma-deneyi-317.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/sekonder-sarginin-sebeke-frekansinda-gerilime-dayanma-deneyi-317.html#comments</comments>
		<pubDate>Sun, 19 Apr 2009 21:59:45 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Akım Gerilim Trafoları]]></category>
		<category><![CDATA[Dayanma]]></category>
		<category><![CDATA[Deneyi]]></category>
		<category><![CDATA[Frekansında]]></category>
		<category><![CDATA[Gerilime]]></category>
		<category><![CDATA[Sargının]]></category>
		<category><![CDATA[şebeke]]></category>
		<category><![CDATA[sekonder]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=317</guid>
		<description><![CDATA[Sekonder Sargının Şebeke Frekansında Gerilime Dayanma Deneyi Deney, 3kV etken değerli bir alternatif gerilim ile yapılmalıdır. Deney gerilimi, pratik olarak sinüs eğrisi biçimli ve frekansı 25-400Hz arasında uygun değerde olmalıdır. Yalnızca bir sekonder sargısı bulunan gerilim transformatöründe deney gerilimi, sargının aralarında bağlanmış uçları ile toprak arasına 1 dakika süre ile uygulanmalıdır. Deneyde, gövde, varsa kazan, [...]]]></description>
			<content:encoded><![CDATA[<p><strong>Sekonder Sargının Şebeke Frekansında Gerilime Dayanma Deneyi</strong><br />
Deney, 3kV etken değerli bir alternatif gerilim ile yapılmalıdır. Deney gerilimi,<br />
pratik olarak sinüs eğrisi biçimli ve frekansı 25-400Hz arasında uygun değerde<br />
olmalıdır.<br />
Yalnızca bir sekonder sargısı bulunan gerilim transformatöründe deney gerilimi,<br />
sargının aralarında bağlanmış uçları ile toprak arasına 1 dakika süre ile<br />
uygulanmalıdır.<span id="more-317"></span><br />
Deneyde, gövde, varsa kazan, topraklanması öngörülmüşse magnetik devre ve<br />
primer sargının bütün uçları ve varsa sekonder sargının öteki kısımları önceden<br />
aralarında bağlanmış ve topraklanmış olmalıdır.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/sekonder-sarginin-sebeke-frekansinda-gerilime-dayanma-deneyi-317.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Topraklanmış Gerilim Transformatöründe Primer Sargının Şebeke Frekansında Gerilime Dayanma Deneyi</title>
		<link>http://www.indiriniz.com/akim-gerilim-trafolari/topraklanmis-gerilim-transformatorunde-primer-sarginin-sebeke-frekansinda-gerilime-dayanma-deneyi-310.html</link>
		<comments>http://www.indiriniz.com/akim-gerilim-trafolari/topraklanmis-gerilim-transformatorunde-primer-sarginin-sebeke-frekansinda-gerilime-dayanma-deneyi-310.html#comments</comments>
		<pubDate>Sun, 19 Apr 2009 21:55:58 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Akım Gerilim Trafoları]]></category>
		<category><![CDATA[Dayanma]]></category>
		<category><![CDATA[Deneyi]]></category>
		<category><![CDATA[Frekansında]]></category>
		<category><![CDATA[gerilim]]></category>
		<category><![CDATA[Gerilime]]></category>
		<category><![CDATA[primer]]></category>
		<category><![CDATA[Sargının]]></category>
		<category><![CDATA[şebeke]]></category>
		<category><![CDATA[topraklanmış]]></category>
		<category><![CDATA[Transformatöründe]]></category>

		<guid isPermaLink="false">http://www.indiriniz.com/?p=310</guid>
		<description><![CDATA[Topraklanmış Gerilim Transformatöründe Primer Sargının Şebeke Frekansında Gerilime Dayanma Deneyi Topraklanmış gerilim transformatörlerinde primer sargının şebeke frekansında dayanma deneyi, IEC 60044-2 Clause 6.1.2.2’ de açıklandığı gibi endüklenen gerilimle yapılmalıdır. Ancak primer sargının işletmede topraklanması öngörülen ucu deney sırasında da toprağa bağlanmalıdır. Yüksek gerilim sargısının topraklanması öngörülen ucu, gövde kazandan yalıtılmış ise, bu uca 3kV etken [...]]]></description>
			<content:encoded><![CDATA[<p><strong>Topraklanmış Gerilim Transformatöründe Primer Sargının Şebeke<br />
Frekansında Gerilime Dayanma Deneyi</strong><br />
Topraklanmış gerilim transformatörlerinde primer sargının şebeke frekansında<br />
dayanma deneyi, IEC 60044-2 Clause 6.1.2.2’ de açıklandığı gibi endüklenen<br />
gerilimle yapılmalıdır. Ancak primer sargının işletmede topraklanması öngörülen<br />
ucu deney sırasında da toprağa bağlanmalıdır.<span id="more-310"></span><br />
Yüksek gerilim sargısının topraklanması öngörülen ucu, gövde kazandan yalıtılmış ise,<br />
bu uca 3kV etken değerli bir gerilim 1 dakika süre ile uygulanmalıdır.<br />
Bu test sırasında, metal muhafaza ve çekirdeğin topraklanması düşünülüyorsa, bunlar<br />
ve tüm sekonder klemensler ortak olarak topraklanmalıdır.<br />
Deney sırasında ve sonrasında, sargılarda hiçbir atlama olmamalı sargı bu sürede<br />
uygulanan gerilime dayanmalıdır.</p>
<p><script type="text/javascript"><!--
google_ad_client = "pub-5297367235498257";
/* 728x15, oluşturulma 20.11.2008 */
google_ad_slot = "6035974834";
google_ad_width = 728;
google_ad_height = 15;
//-->
</script>
<script type="text/javascript"
src="http://pagead2.googlesyndication.com/pagead/show_ads.js">
</script></p> ]]></content:encoded>
			<wfw:commentRss>http://www.indiriniz.com/akim-gerilim-trafolari/topraklanmis-gerilim-transformatorunde-primer-sarginin-sebeke-frekansinda-gerilime-dayanma-deneyi-310.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

